Accuracy of Bubble Velocity Measurement with a Four-point Optical Fibre Probe

نویسندگان

  • Wei BAI
  • Niels G. DEEN
  • Robert F. MUDDE
چکیده

For the operation of high void fraction bubbly flows in bubble columns, insight in primary parameters such as bubble size, shape and velocity as well as gas volume fraction is essential. At high gas volume fractions the flow system becomes opaque, ruling out non-intrusive optical techniques. As an alternative optical fibre probes can be used, which have the advantage of low cost, simplicity of setup and easy interpretation of the results. By using four-point optical fibre probe, properties of bubbles can be studied, such as bubble velocity, bubble size, etc. However, the effect of bubble wobbling behaviour and physical properties of liquids on the accuracy of the velocity measurements has not been investigated in detail. In the present study, the performance of a four-point optical fibre probe was evaluated for five different liquids. The probe performance and causes of inaccuracies are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bubble properties of heterogeneous bubbly flows in a square bubble column

The present work focuses on the measurements of bubble properties in heterogeneous bubbly flows in a square bubble column. A four-point optical fibre probe was used for this purpose. The accuracy and intrusive effect of the optical probe was investigated first. The results show that the optical probe underestimates bubble properties, such as, bubble velocity, local void fraction. The presence o...

متن کامل

Application of New Inflection Point Method for Hydrodynamics Study in Slurry Bubble Column Reactors

Bubble column reactors are used in a wide variety of applications such as multiphase bioreactors, catalytic slurry reactors, and absorption processes. The superficial gas velocity-gas holdup relationship and transition point are two important parameters for characterizing the hydrodynamics of a bubble column reactor. In this study, systematic investigation of a nitrogen - water - glass bead...

متن کامل

Raman Spectra of a PMMA Microstructured Optical Fibre and Direct Measurement of Its Gain Coefficient

 A polymethylmethacrylate (PMMA) microstructured polymer optical fiber (mPOF) is fabricated and characterized. Using the cut-back technique the fiber loss is measured which is higher than the step-index silica fibers. Through a novel experimental scheme, the backward Stokes spectrum of the fabricated mPOF is recorded over a range exceeding 3000 cm‑1 during the cut-back method and compared ...

متن کامل

Local Holdups and Phase Propagation Velocity Measurement in GLSCFB Riser Using Electrical Resistance Tomography and Optical Fibre Probe

The application of Gas-Liquid-solid circulating fluidized beds (GLSCBE) has increased recently in chemical, petrochemical and biochemical industries. Electrical Resistance Tomography (ERT) and optical fibre probe were applied to investigate local phase holdups distribution. Since ERT is applicable only to conductive phase(s), e.g. liquid phase in this study, optical fibre probe was employed sim...

متن کامل

Optical Fibre Interferometric System for Doppler Effect Measurement

The optical fibre laser Doppler velocimetry (LDV) is a technique used for the velocity measurement of fluid flows. The two-dimensional directional LDV using a special technique based on generation of heterodyne signals of differential carrier frequencies has been described in literature [1,2]. The capability of simultaneous measurement of three orthogonal velocity components has also been prese...

متن کامل