چکیده

The ability to obtain comprehensive structural and functional information from intact biological tissue in vivo is highly desirable for many important biomedical applications, including cancer and brain studies. Here, we developed a fully integrated multimodal microscopy that can provide photoacoustic (optical absorption), two-photon (fluorescence), and second harmonic generation (SHG) information from tissue in vivo, with intrinsically co-registered images. Moreover, using a delicately designed optical-acoustic coupling configuration, a high-frequency miniature ultrasonic transducer was integrated into a water-immersion optical objective, thus allowing all three imaging modalities to provide a high lateral resolution of ~290 nm with reflection-mode imaging capability, which is essential for studying intricate anatomy, such as that of the brain. Taking advantage of the complementary and comprehensive contrasts of the system, we demonstrated high-resolution imaging of various tissues in living mice, including microvasculature (by photoacoustics), epidermis cells, cortical neurons (by two-photon fluorescence), and extracellular collagen fibers (by SHG). The intrinsic image co-registration of the three modalities conveniently provided improved visualization and understanding of the tissue microarchitecture. The reported results suggest that, by revealing complementary tissue microstructures in vivo, this multimodal microscopy can potentially facilitate a broad range of biomedical studies, such as imaging of the tumor microenvironment and neurovascular coupling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ast 3 - D dark - field reflection - mode photoacoustic icroscopy in vivo with a 30 - MHz ultrasound inear array

ihong V. Wang ashington University in St. Louis ptical Imaging Laboratory epartment of Biomedical Engineering t. Louis, Missouri 63130 -mail: [email protected] Abstract. We present an in vivo dark-field reflection-mode photoacoustic microscopy system that performs cross-sectional B-scan imaging at 50 Hz with real-time beamforming and 3-D imaging consisting of 166 B-scan frames at 1 Hz wit...

متن کامل

Tissue Spectroscopic Characterization Based on Fluorescence , Second Harmonic Generation , and Reflected Light

The diagnosis of many diseases often requires a histological analysis of tissues. Histology analysis compares the microscopic structure of a tissue specimen with an image database containing known physiological and pathological tissue structures. Three new microscopy technologies are developed to complement histology based on novel contrast mechanisms to better visualize and understand tissue s...

متن کامل

In vivo dark-field reflection-mode photoacoustic microscopy.

Reflection-mode photoacoustic microscopy with dark-field laser pulse illumination and high-numerical-aperture ultrasonic detection is designed and implemented in noninvasively imaged blood vessels in the skin in vivo. Dark-field optical illumination minimizes the interference caused by strong photoacoustic signals from superficial structures. A high-numerical-aperture acoustic lens provides hig...

متن کامل

Use of a single-mode fiber coupler for second-harmonic-generation microscopy.

We present a compact second-harmonic-generation (SHG) microscope based on a three-port single-mode fiber coupler. The fiber coupler is used to deliver a near-infrared ultrashort-pulsed laser beam as well as to collect the SHG signal in the visible wavelength range. The SHG microscope exhibits an axial resolution of 1.8 microm, which shows a slight enhancement of the optical sectioning effect co...

متن کامل

Fully motorized optical-resolution photoacoustic microscopy.

We have developed fully motorized optical-resolution photoacoustic microscopy (OR-PAM), which integrates five complementary scanning modes and simultaneously provides a high imaging speed and a wide field of view (FOV) with 2.6 μm lateral resolution. With one-dimensional (1D) motion-mode mechanical scanning, we measured the blood flow through a cross section of a blood vessel in vivo. With two-...

متن کامل