Hardware/Software Codesign in a Compact Ion Mobility Spectrometer Sensor System for Subsurface Contaminant Detection

نویسندگان

  • Sin Ming Loo
  • Jonathan P. Cole
  • Molly M. Gribb
چکیده

A field-programmable-gate-array-(FPGA-) based data acquisition and control system was designed in a hardware/software codesign environment using an embedded Xilinx Microblaze soft-core processor for use with a subsurface ion mobility spectrometer (IMS) system, designed for detection of gaseous volatile organic compounds (VOCs). An FPGA is used to accelerate the digital signal processing algorithms and provide accurate timing and control. An embedded soft-core processor is used to ease development by implementing nontime critical portions of the design in software. The design was successfully implemented using a low-cost, off-the-shelf Xilinx Spartan-III FPGA and supporting digital and analog electronics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Field-programmable Gate Array in Miniature Ion Mobility Spectrometer Sensor System

This paper presents the use of field-programmable gate array (FPGA) in a miniature Ion Mobility Spectrometer (IMS) sensor system. This IMS sensor is for detection of subsurface gaseous volatile organic compounds (VOCs). This paper describes how an FPGA is used to process the data collected from the sensor and control its overall operation. A Xilinx Microblaze soft-core processor is used to ease...

متن کامل

A small subsurface ion mobility spectrometer sensor for detecting environmental soil-gas contaminants.

A small subsurface ion mobility spectrometer (SS-IMS) was constructed and tested with several environmental contaminants to determine its potential for monitoring gaseous volatile organic compounds in the vadose zone. Trichloroethylene (TCE) and tetrachloroethylene (PCE) were detected and separated in IMS for the first time. Detection limits as low as 1 part per billion volume-to-volume (ppb(v)...

متن کامل

A wireless sensor system for validation of real-time automatic calibration of groundwater transport models

Please cite this article in press as: Loden, P., et models. J. Syst. Software (2009), doi:10.1016/j.j In this paper, we present the use of a wireless sensor network in a lab for subsurface contaminant plume monitoring with the objective of automatic calibration of groundwater transport models. A tank configured to simulate an aquifer was used as a testbed, and a 2D model was created based on th...

متن کامل

DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD

Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...

متن کامل

A fast codesign approach for low cost application-specific-system on programmable chip (SoPC) : Application to sensor network

Systems on programmable chip, as system on chip, are composed by software and hardware. Therefore a codesign based approach is needed to meet the functional requirements. While classic codesign flows are long and involve complex and expensive design tools, this paper presents a fast but efficient codesign flow. To reduce the design cycle and the total cost of ownership (TCO), the presented desi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • EURASIP J. Emb. Sys.

دوره 2008  شماره 

صفحات  -

تاریخ انتشار 2008