Image guided versus palpation guided core needle biopsy of palpable breast masses: a prospective study

نویسندگان

  • Smriti Hari
  • Swati Kumari
  • Anurag Srivastava
  • Sanjay Thulkar
  • Sandeep Mathur
  • Prasad Thotton Veedu
چکیده

BACKGROUND & OBJECTIVES Biopsy of palpable breast masses can be performed manually by palpation guidance or under imaging guidance. Based on retrospective studies, image guided biopsy is considered more accurate than palpation guided breast biopsy; however, these techniques have not been compared prospectively. We conducted this prospective study to verify the superiority and determine the size of beneficial effect of image guided biopsy over palpation guided biopsy. METHODS Over a period of 18 months, 36 patients each with palpable breast masses were randomized into palpation guided and image guided breast biopsy arms. Ultrasound was used for image guidance in 33 patients and mammographic (stereotactic) guidance in three patients. All biopsies were performed using 14 gauge automated core biopsy needles. Inconclusive, suspicious or imaging-histologic discordant biopsies were repeated. RESULTS Malignancy was found in 30 of 36 women in palpation guided biopsy arm and 27 of 36 women in image guided biopsy arm. Palpation guided biopsy had sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 46.7, 100, 100, 27.3 per cent, respectively, for diagnosing breast cancer. Nineteen of 36 women (52.8%) required repeat biopsy because of inadequate samples (7 of 19), suspicious findings (2 of 19) or imaging-histologic discordance (10 of 19). On repeat biopsy, malignancy was found in all cases of imaging-histologic discordance. Image guided biopsy had 96.3 per cent sensitivity and 100 per cent specificity. There was no case of inadequate sample or imaging-histologic discordance with image guided biopsy. INTERPRETATION & CONCLUSIONS Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی ارزش تشخیص نمونه برداری سوزنی ضایعات پستان با کمک روش های تصویربرداری

The evaluate the diagnostic value of image guided Fine Needle Aspiration (FNA) in breast lesions, the cytologic results of 401 patients were studied. All patients had either unpalpable masses or lesions who were hardly possible to localize by palpation and FNA was performed by single radiologist under ultrasound guide in all cases. The cytologic results were divided into four categories (inconc...

متن کامل

Concordance Rate between Fine Needle Aspiration Biopsy and Core Needle Biopsy in Breast Lesions

Background and Objectives:Breast cancer is the most common cancer among women worldwide. Fine needle aspiration biopsy (FNAB) is one of the methods of breast biopsy which is fast, easy and cost effective. The aim of this study was to evaluate the concordance rate between pathologic results of sonography or stereotaxy guided FNAB and guided core needle biopsy (CNB) in the evaluation of breast le...

متن کامل

US-guided core breast biopsy: use and cost-effectiveness.

PURPOSE To determine the frequency with which ultrasonographically (US) guided core biopsy obviated diagnostic surgical biopsy of nonpalpable breast masses, to calculate the cost savings of diagnosis attributable to US-guided core biopsy, and to compare the costs of US-guided versus stereotactically guided core biopsy. MATERIALS AND METHODS US-guided core biopsy was performed in 151 consecuti...

متن کامل

Fine-needle aspiration cytology of the breast.

Fine-needle aspiration cytology (FNAC) is an established, highly accurate, and cost-effective method for diagnosing lesions in different organs, including the breast. The method is minimally invasive without unwanted side effects. FNAC forms part of the triple assessment of breast lesions. Despite some shortcomings of the reporting categories, FNAC as part of the triple assessment has proved it...

متن کامل

Ultrasound guided fine needle aspiration cytology versus core biopsy in the preoperative assessment of non-palpable breast lesions.

BACKGROUND Breast screening is a method of detecting breast cancer at a very early stage. Most of the lesions detected by screening are not malignant. Objective of this study was to compare ultrasound guided fine needle aspiration cytology and core biopsy in the preoperative assessment of non-palpable breast lesions. METHODS The study was conducted prospectively at Department of Radiology, Sh...

متن کامل