Measuring peripheral resistance and conduit arterial structure in humans using Doppler ultrasound.
نویسندگان
چکیده
The purpose of this study was to establish valid indexes of conduit and resistance vessel structure in humans by using edge detection and wall tracking of high-resolution B-mode arterial ultrasound images, combined with synchronized Doppler waveform envelope analysis, to calculate conduit artery blood flow and diameter continuously across the cardiac cycle. Nine subjects aged 36.7 (9.2) yr underwent, on separate days, assessment of brachial artery blood flow and diameter response to 5-, 10-, and 15-min periods of forearm ischemia in the presence and absence of combined sublingual glyceryl trinitrate (GTN) administration. Two further sessions examined responses to ischemic exercise, one in combination with GTN. The peak brachial artery diameter was observed in response to the combination of ischemic exercise and GTN; a significant difference existed between resting brachial artery diameter and peak brachial artery diameter, indicating that resting diameter may be a poor measure of conduit vessel structure in vivo. Peak brachial artery flow was also observed in response to a combination of forearm ischemia exercise and GTN administration, the response being greater than that induced by periods of ischemia, GTN, or ischemic exercise alone. These data indicate that noninvasive indexes of conduit and resistance vessel structure can be simultaneously determined in vivo in response to a single, brief, stimulus and that caution should be applied in using resting arterial diameter as a surrogate measure of conduit artery structure in vivo.
منابع مشابه
Innovative Methodology Measuring peripheral resistance and conduit arterial structure in humans using Doppler ultrasound
Naylor, Louise H., Cara J. Weisbrod, Gerry O’Driscoll, and Daniel J. Green. Measuring peripheral resistance and conduit arterial structure in humans using Doppler ultrasound. J Appl Physiol 98: 2311–2315, 2005. First published February 3, 2005; doi:10.1152/japplphysiol.01047.2004.— The purpose of this study was to establish valid indexes of conduit and resistance vessel structure in humans by u...
متن کاملAssessment of voluntary rhythmic muscle contraction-induced exercising blood flow variability measured by Doppler ultrasound
Given recent technological developments, ultrasound Doppler can provide valuable measurements of blood velocity/flow in the conduit artery with high temporal resolution. In human-applied science such as exercise physiology, hemodynamic measurements in the conduit artery is commonly performed by blood flow feeding the exercising muscle, as the increase in oxygen uptake (calculated as a product o...
متن کاملPresentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملPeripheral vascular changes after electrically stimulated cycle training in people with spinal cord injury.
OBJECTIVE To test whether a short period of training leads to adaptations in the cross-sectional area of large conduit arteries and improved blood flow to the paralyzed legs of individuals with spinal cord injury (SCI). DESIGN Before-after trial. SETTING Rehabilitation center, academic medical center. PARTICIPANTS Nine men with spinal cord lesions. INTERVENTION Six weeks of cycling usin...
متن کاملMeasurement of the exercising blood flow during rhythmical muscle contractions assessed by Doppler ultrasound: Methodological considerations
Given the recent technological developments, ultrasound Doppler can provide valuable measurements of arterial blood flow with high temporal resolution. In a clinical setting, measurements of hemodynamics is used to monitor, diagnose and manage changes in blood velocity profile for cardiac valve disease, relatively large vessel stenosis and other cardiovascular diseases. In health science and pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 98 6 شماره
صفحات -
تاریخ انتشار 2005