Robust fault tolerant control of DFIG wind energy systems with unknown inputs
نویسندگان
چکیده
This paper proposes a Fuzzy Dedicated Observers (FDOS) method using a Nonlinear Unknown Input Fuzzy Observer (UIFO) with a Fuzzy Scheduler Fault Tolerant Control (FSFTC) algorithm for fuzzy Takagi-Sugeno (TS) systems subject to sensor faults, parametric uncertainties, and time varying unknown inputs. FDOS provide residuals for detection and isolation of sensor faults which can affect a TS model. The TS fuzzy model is adopted for fuzzy modeling of the uncertain nonlinear system and establishing fuzzy state observers. The concept of Parallel Distributed Compensation (PDC) is employed to design FSFTC and fuzzy observers from the TS fuzzy models. TS fuzzy systems are classified into three families based on the input matrices and a FSFTC synthesis procedure is given for each family. In each family, sufficient conditions are derived for robust stabilization, in the sense of Taylor series stability and Lyapunovmethod, for the TS fuzzy system with parametric uncertainties, sensor faults, and unknown inputs. The sufficient conditions are formulated in the format of Linear Matrix Inequalities (LMIs). The effectiveness of the proposed controller design methodology is finally demonstrated through a wind energy system with Doubly Fed Induction Generators (DFIG) to illustrate the effectiveness of the proposed method. 2012 Elsevier Ltd. All rights reserved.
منابع مشابه
Sensor Fault Tolerant Control For DFIG With WECS
Wind Energy Conversion Systems are the most striking renewable energy resources available to generate the electricity. Doubly-fed Induction Generator (DFIG) based wind turbine with variable speed is the most common wind turbine in the growing wind market. In any WECS, power flow must be maintained at all instant irrespective of any fault in the system. This paper deals with fault tolerant contr...
متن کاملFault-Tolerant Control using Adaptive Time-Frequency Method in Bearing Fault Detection for DFIG Wind Energy System
With the advances in power electronic technology, doubly-fed induction generators (DFIG) have increasingly drawn the interest of the wind turbine industry. To ensure the reliable operation and power quality of wind power systems, the fault-tolerant control for DFIG is studied in this paper. The faulttolerant controller is designed to maintain an acceptable level of performance during bearing fa...
متن کاملRobust Model- Based Fault Detection and Isolation for V47/660kW Wind Turbine
In this paper, in order to increase the efficiency, to reduce the cost and to prevent the failures of wind turbines, which lead to an extensive break down, a robust fault diagnosis system is proposed for V47/660kW wind turbine operated in Manjil wind farm, Gilan province, Iran. According to the acquired data from Iran wind turbine industry, common faults of the wind turbine such as sensor fault...
متن کاملFPGA-based reconfigurable control for switch fault tolerant operation of WECS with DFIG without redundancy
This paper deals with reconfigurable back-to-back converter topology and control orders in Wind Energy Conversion Systems (WECS). A typical WECS with Doubly Fed Induction Generator (DFIG) in balanced conditions is concerned. Based on the classical topology, a fault tolerant converter without any redundancy has been studied. The presented fault tolerant topology allows a “five-leg” structure wit...
متن کامل