Insertion torque, pull-out strength and cortical bone thickness in contact with orthodontic mini-implants at different insertion angles.

نویسندگان

  • Thiago Martins Meira
  • Orlando Motohiro Tanaka
  • Maiara Medeiros Ronsani
  • Ivan Toshio Maruo
  • Odilon Guariza-Filho
  • Elisa Souza Camargo
  • Hiroshi Maruo
چکیده

This study aimed to evaluate biomechanical behaviour of inclined orthodontic mini-implants by analyzing its insertion torque (IT), axial pull-out strength (APS), and cortical bone thickness in contact with mini-implant (CBTC). A total of 102 mini-implants were inserted at 90 degree, 60 degree, and 45 degree to the surface of synthetic bone. Peak IT was measured, and the mini-implants were aligned with the mechanical testing machine to record the APS. The cortical bone thickness in contact with each mini-implant was measured after the pull-out test and the data were subjected to statistical analyses. The 45 degree group had a significantly higher IT compared with the 90 degree group (P < 0.05). There was a statistically significant increase in the average of cortical bone thickness in CBTC across the three groups (P < 0.05). A negative correlation between the angulation and the CBTC (r = -0.95, P < 0.05) and a positive correlation between the APS and the CBTC were observed (r = 0.34, P < 0.05). Mini-implants that are inserted more inclined to the surface of the bone provide greater IT and an increased contact with the cortical bone. The greater the CBTC, the greater is the APS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque

OBJECTIVE To determine the unique contribution of geometrical design characteristics of orthodontic mini-implants on maximum insertion torque while controlling for the influence of cortical bone thickness. METHODS Total number of 100 cylindrical orthodontic mini-implants was used. Geometrical design characteristics of ten specimens of ten types of cylindrical self-drilling orthodontic mini-im...

متن کامل

Insertion torque versus mechanical resistance of mini-implants inserted in different cortical thickness

OBJECTIVE This study aimed to measure insertion torque, tip mechanical resistance to fracture and transmucosal neck of mini-implants (MI) (Conexão Sistemas de PróteseT), as well as to analyze surface morphology. METHODS Mechanical tests were carried out to measure the insertion torque of MIs in different cortical thicknesses, and tip mechanical resistance to fracture as well as transmucosal n...

متن کامل

Insertion Torques of Self-Drilling Mini-Implants in Simulated Mandibular Bone: Assessment of Potential for Implant Fracture.

PURPOSE Fracture of orthodontic mini-implants during insertion is a limiting factor for their clinical success. The purpose of this study was to determine the fracture potential of commonly used self-drilling orthodontic mini-implants when placed into simulated thick, dense mandibular bone. MATERIALS AND METHODS Six mini-implant systems were assessed for the potential for fracture (Aarhus, Me...

متن کامل

Influence of Screw Length and Bone Thickness on the Stability of Temporary Implants

The purpose of this work was to study the influence of screw length and bone thickness on the stability of temporary implants. A total of 96 self-drilling temporary screws with two different lengths were inserted into polyurethane blocks (n = 66), bovine femurs (n = 18) and rabbit tibia (n = 12) with different cortical thicknesses (1 to 8 mm). Screws insertion in polyurethane blocks was assiste...

متن کامل

Influence of cortical thickness on the stability of mini-implants with microthreads.

The objective of this study was to assess the influence of cortical thickness and bone density on the insertion torque of a mini-implant (MI) with microthreads. Mini-implants with lengths of 6 and 8 mm in the active part were inserted into synthetic bone blocks (polyurethane resin). The density of these blocks was 20 pounds per cubic foot (pcf), simulating bone marrow, and that of blocks 1, 2, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 35 6  شماره 

صفحات  -

تاریخ انتشار 2013