We report here an enzyme-amplified, sandwich-type immunosensor for detecting the biospecific interaction between an antibody and antigen using redox mediation. We employed biotin/anti-biotin IgG as a model immunosensing pair. Partially ferrocenyl-tethered dendrimer (Fc-D), whose ferrocene moiety acts as a redox mediator, was immobilized to the electrode surface by covalent binding between the dendrimer amines and the carboxylic acids of a self-assembled monolayer. The unreacted amines of the immobilized Fc-D were modified with biotin groups to allow the specific binding of goat anti-biotin IgG. Rabbit anti-goat IgG-conjugated alkaline phosphatase was bound to goat anti-biotin IgG to catalyze conversion of p-aminophenyl phosphate monohydrate to p-aminophenol. This product is oxidized to quinoimide by the reduction of ferrocenium back to ferrocene, producing an electrocatalytic anodic current. Cyclic voltammograms and surface plasmon resonance experiments showed that the binding of nonspecific proteins is not significant on the biotinylated Fc-D surface. We also examined the change in peak current according to the concentration of anti-biotin IgG and found that the detection range of this immunosensing scheme is between 0.1 and 30 microg mL(-1).
منابع مشابه
Functionalization of a poly(amidoamine) dendrimer with ferrocenyls and its application to the construction of a reagentless enzyme electrode.
Poly(amidoamine) dendrimers having various degrees of modification with the redox-active ferrocenyls were prepared by controlling the molar ratio of ferrocenecarboxaldehyde to amine groups of dendrimers. By alternate layer-by-layer depositions of partial ferrocenyl-tethered dendrimers (Fc-D) with periodate-oxidized glucose oxidase (GOx) on a Au surface, an electrochemically and enzymatically ac...
متن کاملAn electrochemical immunosensor using p-aminophenol redox cycling by NADH on a self-assembled monolayer and ferrocene-modified Au electrodes.
Redox cycling of enzymatically amplified electroactive species has been widely employed for high signal amplification in electrochemical biosensors. However, gold (Au) electrodes are not generally suitable for redox cycling using a reducing (or oxidizing) agent because of the high background current caused by the redox reaction of the agent at highly electrocatalytic Au electrodes. Here we repo...
متن کاملEnzyme-amplified electrochemical detection of DNA using electrocatalysis of ferrocenyl-tethered dendrimer.
We have developed a sandwich-type enzyme-linked DNA sensor as a new electrochemical method to detect DNA hybridization. A partially ferrocenyl-tethered poly(amidoamine) dendrimer (Fc-D) was used as an electrocatalyst to enhance the electronic signals of DNA detection as well as a building block to immobilize capture probes. Fc-D was immobilized on a carboxylic acid-terminated self-assembled mon...
متن کاملA nanocatalyst-based assay for proteins: DNA-free ultrasensitive electrochemical detection using catalytic reduction of p-nitrophenol by gold-nanoparticle labels.
This communication reports a nanocatalyst-based electrochemical assay for proteins. Ultrasensitive detection has been achieved by signal amplification combined with noise reduction: the signal is amplified both by the catalytic reduction of p-nitrophenol to p-aminophenol by gold-nanocatalyst labels and by the chemical reduction of p-quinone imine to p-aminophenol by NaBH4; the noise is reduced ...
متن کاملAffinity biosensor for avidin using a double functionalized dendrimer monolayer on a gold electrode.
We have developed an affinity biosensor system based on avidin-biotin interaction on a gold electrode. As the building block of an affinity-sensing monolayer, a fourth-generation (G4) poly(amidoamine) dendrimer having partial ferrocenyl-tethered surface groups was prepared and used. The unmodified surface amine groups from dendrimers were functionalized with biotinamidocaproate, and the biotiny...