Validation of photoplethysmography as a method to detect heart rate during rest and exercise.
نویسندگان
چکیده
Despite their enhanced marketplace visibility, validity of wearable photoplethysmographic heart rate monitoring is scarce. Forty-seven healthy participants performed seven, 6-min exercise bouts and completed a valid skin type scale. Participants wore an Omron HR500U (OHR) and a Mio Alpha (MA), two commercial wearable photoplethysmographic heart rate monitors. Data were compared to a Polar RS800CX (PRS). Means and error were calculated between devices using minutes 2-5. Compared to PRS, MA data was significantly different in walking, biking (2.41 ± 3.99 bpm and 3.26 ± 11.38 bpm, p < 0.05) and weight lifting (23.30 ± 31.94 bpm, p < 0.01). OHR differed from PRS in walking (4.95 ± 7.53 bpm, p < 0.05) and weight lifting (4.67 ± 8.95 bpm, p < 0.05). MA during elliptical, stair climbing and biking conditions demonstrated a strong correlation between jogging speed and error (r = 0.55, p < 0.0001), and showed differences in participants with less photosensitive skin.
منابع مشابه
Synergic effect of aerobic exercise training (Moderate Intensity) and Soya Intake on Blood Pressure & Rest Heart Rate in Obese Postmenopausal Women
Introduction: In synergic effect of exercise training on reducing cardiovascular disease, soy is a useful source of food in reducing blood pressure and control of heart rate. The purpose of this study was to investigate the synergic effect of short aerobic moderate intensity exercise and soya intake on blood pressure & rest heart rate in obese postmenopausal women. Methods: The present study...
متن کاملEffects of Wearing N95 Respirators and Surgical Masks during Progressive Running Exercise and High-Intensity Interval Training on Time- and Frequency-Domain Indicators of Heart Rate Variability
Background and purpose: Wearing face masks has become popular during the COVID-19 pandemic as a measure to prevent the spread of the virus. Some studies have pointed out the intervening role of these masks in the effect of exercise on the cardiovascular system. This study aimed at examining and comparing the effects of masking (N95 respirators and surgical masks) and not wearing a mask during e...
متن کاملDescription of a Database Containing Wrist PPG Signals Recorded during Physical Exercise with Both Accelerometer and Gyroscope Measures of Motion
Abstract: Wearable heart rate sensors such as those found in smartwatches are commonly based upon Photoplethysmography (PPG) which shines a light into the wrist and measures the amount of light reflected back. This method works well for stationary subjects, but in exercise situations, PPG signals are heavily corrupted by motion artifacts. The presence of these artifacts necessitates the creatio...
متن کاملPost-exercise heart rate variability in the acceleration photoplethysmogram
There is a limited number of studies on heart rate variability (HRV) dynamics immediately after exercise. It is well-known that the electrocardiogram is a non-invasive method that can be used to measure heart rate variability (HRV) at rest and after exercise. Photoplethysmogram (PPG) signals also reflect the cardiac rhythm since the mechanical activity of the heart is coupled to its electrical ...
متن کاملLightweight wrist photoplethysmography for heavy exercise: motion robust heart rate monitoring algorithm
The challenge of heart rate monitoring based on wrist photoplethysmography (PPG) during heavy exercise is addressed. PPG is susceptible to motion artefacts, which have to be mitigated for accurate heart rate estimation. Motion artefacts are particularly apparent for wrist devices, for example, a smart watch, because of the high mobility of the arms. Proposed is a low complexity highly accurate ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of medical engineering & technology
دوره 39 5 شماره
صفحات -
تاریخ انتشار 2015