Detailed multigrade evaluation of fetal disorders with the quantified actocardiogram.

نویسندگان

  • Kazuo Maeda
  • Tomio Iwabe
  • Souichi Yoshida
  • Takashi Ito
  • Yukihisa Minagawa
  • Seiichi Morokuma
  • Ritsuko K Pooh
  • Taisuke Fuchiwaki
چکیده

AIMS To evaluate fetal disorders using detailed quantitative values from the actocardiogram (ACG) involving simultaneous tracing of ultrasonic Doppler fetal movement bursts and fetal heart rate (FHR). METHODS Duration of FHR accelerations and fetal movement bursts were measured manually in 20 common fetal disorders. The severity of the fetal disorder was estimated using the FHR acceleration duration to movement burst ratio (A/B ratio) and 10-0 clinical severity ranks derived from the A/B ratio. The correlation of the A/B ratio and 1 and 5 min Apgar scores, as well as numerically expressed long-term outcomes were studied. RESULTS A/B ratios were significantly correlated with the 1 and 5 min Apgar scores and the numerically evaluated long-term outcomes. Controversial cases of FHR pattern were more easily understood using the A/B ratio. The 10-0 severity derived from the A/B ratio was useful in clinical fetal studies. CONCLUSION Common fetal disorders were evaluated quantitatively and in more detail using the A/B ratio from the actocardiogram than when using common binary good or bad evaluation. The A/B ratio was useful in outcome estimation, where the prognostic capability of the A/B ratio was confirmed by significant correlation with 1 and 5 min Apgar scores and long-term outcomes of fetal disorders.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fetal Diagnosis with Ultrasonic Actocardiogram and GLHW Tissue Characterization

Actocardiogram: Ultrasonic Doppler actocardiogram was simultaneous tracing of FHR and fetal movement signals on the monitoring chart, created in 1984 by Maeda. Fetal behavior was easily studied, false-positive nonreactive FHR and physiological sinusoidal FHR were differentiated, the severity of fetal CNS lesion and common fetal disorders were determined, short and long-term outcomes were diagno...

متن کامل

Quantitative studies on fetal actocardiogram.

AIM To quantitatively analyze actocardiography as a method to differentiate between active and resting fetal states. METHODS We established five new quantitative parameters for actocardiogram; they include duration, occupancy, and frequency of movement bursts, and fetal heart rate acceleration to movement ratio (A/B ratio) in duration and number. These parameters were analyzed and compared in...

متن کامل

The ultrasonic Doppler fetal actocardiogram and its computer processing.

Gross fetal movement was detected using a lower frequency ultrasonic Doppler shift than that used in the study of fetal heart action. The movement signal was changed into deflection which was recorded on CTG chart simultaneously with the fetal heart rate (FHR), and was called the fetal actocardiogram. Visual analysis of the actocardiogram showed bursts of active fetal movements in the active fe...

متن کامل

O-45: Quantification of Cell-Free-Fetal-DNAfrom Maternal Plasma for the First Time in Pakistan:Implications for Non-Invasive PrenatalDiagnosis of Genetic Disorders

Background: Current prenatal diagnosis requires invasive testing which carries a 1-4% procedure-related-risk of miscarriage; hence, non-invasive techniques are desired. The recent demonstration of cell-free-fetal-DNA enriched from maternal plasma has opened new possibilities for non-invasive-prenatal-diagnosis of not only genetic-disorders such as β-thalassaemia and haemophilia but also chromos...

متن کامل

Quantitative Analysis of Fetal Actocardiogram: Update

Actocardiogram (ACG): The ACG simultaneously traced FHR curve and fetal movement signals. The MHz level continuous wave (CW) ultrasound was used, of which SPTA intensity was as weak as 1 mW/cm2. The fetal movement Doppler signals obtained by 2 MHz source ultrasound was 20-50 Hz. The ultrasound detected Doppler fetal heart beat signals at the same time, of which Doppler frequency was 100 or more...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of perinatal medicine

دوره 37 4  شماره 

صفحات  -

تاریخ انتشار 2009