Clinical performance of posterior metal-free polymer crowns with and without fiber reinforcement: one-year results of a randomised clinical trial.

نویسندگان

  • Brigitte Ohlmann
  • Jens Dreyhaupt
  • Marc Schmitter
  • Olaf Gabbert
  • Alexander Hassel
  • Peter Rammelsberg
چکیده

OBJECTIVES The aim of this study was to evaluate the clinical performance of posterior, metal-free polymer crowns with and without a glass-fiber framework, in comparison to metal-ceramic crowns. METHODS After randomisation, 80 single crowns, manufactured from a newly designed polymer composite, were set in posterior teeth. Half of these received a glass-fiber framework, while half were prepared without any framework stabilisation. All polymer crowns were adhesively luted with resin cement. As the control group, 40 conventional metal-ceramic crowns were inserted with hybrid cement. Documentation included failures and other complications, as well as gingival/plaque status and aesthetic performance. RESULTS During the 12-month observation period, eight polymer crowns and three metal-ceramic crowns showed clinically relevant complications. The most frequent complications were root canal treatments (n=4) and decementation (n=4) of the crowns. A total of two crowns (one polymer crown with fiber network and one crown of the control group) had to be replaced. After 12 months, polymer crowns with glass-fiber framework exhibited significantly higher plaque accumulation (p=0.005) and gingival index (p=0.04) than metal-ceramic crowns, while no significant differences could be demonstrated for polymer crowns without fiber reinforcement. Postoperative sensibility and aesthetic performance did not differ significantly between the groups. CONCLUSIONS Within a 12-month observation period, posterior polymer crowns with and without glass-fiber framework demonstrated acceptable stability and aesthetic performance. Polymer crowns with fiber framework showed significant higher plaque accumulation and gingival index than metal-ceramic crowns.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical performance of metal-free polymer crowns after 3 years in service.

OBJECTIVE To investigate the influence of location and preparation design on the survival and complication rate of metal-free polymer crowns within a prospective clinical study. METHODS After randomization, a total of 114 (68 posterior and 46 anterior) single crowns were prepared, either with a chamfer finishing line or with a shoulder combined with occlusal reduction of at least 1 mm. Build-...

متن کامل

Cynara scolymus L. in Treatment of Hypercholesterolemic Type 2 Diabetic Patients: a Randomized Double-Blind Placebo-Controlled Clinical Trial

Background: Type 2 diabetes mellitus with hyperlipidemia is a common disease. Conventional anti-hyperglycemic and anti-hyperlipidemic drugs have limited efficacies and important side effects, so that alternative agents are needed. Previous studies suggest that fiber-free artichoke (Cynara scolymus L.) leaf extract may have anti-hyperglycemic and anti-hypercholesterolemic effects in hypercholest...

متن کامل

Outcome of short implants as an alternative to sinus lift surgery and standard-length implants for rehabilitation of atrophic posterior maxilla: A clinical trial

Background and Aims: The aim of this study was to assess the outcome of short implants (<8 mm length) as an alternative to sinus lift surgery and placement of standard-length implants (10-12 mm length) for rehabilitation of atrophic posterior maxilla. Materials and Methods: In this prospective clinical trial, 26 patients with 6-7 mm of residual alveolar bone height in their atrophic posterior ...

متن کامل

Effect of Reinforcement Type on the Tension Stiffening Model of Ultra-High Performance Concrete (UHPC)

Ultra-high performance concrete (UHPC) is a developing concrete and today is increasing to interest using it in structures due to its advantages such as high-compressive strength, modulus of elasticity, highly durability and low-permeability. Therefore, it is necessary to provide models for prediction of nonlinear behavior of this material. This study is aimed to investigate the tension-stiffen...

متن کامل

The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study

The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study Dr. M. Rismanchian * - Dr. R. Birang ** * Assistant Professor of Fixed Prosthodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Assistant Professor of Periodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of dentistry

دوره 34 10  شماره 

صفحات  -

تاریخ انتشار 2006