Improvement in the determination of mancozeb residues by the carbon disulfide evolution method using flow injection analysis.

نویسندگان

  • D Bohrer
  • P Cicero Do Nascimento
  • H M Gomes
چکیده

The sample decomposition of the carbon disulfide evolution method for the determination of dithiocarbamate residues was carried out in a closed vial in the presence of hexane. The evolved carbon disulfide was extracted by the organic solvent and injected in a flow system for its quantification as copper complex. The conditions for batch decomposition, flow injection determination, and association of both were investigated with sodium diethyldithiocarbamate as model substance. An one-channel flow system was employed where the carrier stream was the ethanolic ethylenediamine/copper solution. The determination range was of 0. 01-1.26 microg of CS(2), with a relative standard deviation of 0.06% (n = 10), with a sample throughput of 45 samples/h. The association of the batch decomposition with the flow system was carried out with the fungicide mancozeb and was applied to the analysis of its residue in potato, lettuce, cucumber, and green bean crops. The approach allowed the analysis of 11 samples in triplicate in 2 h, with recoveries between 85% and 92% and relative standard deviation about 2%.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pesticide residue monitoring in green beans from Souss-massa (Morocco) and half-life times of dithiocarbamate fungicide on green beans after field treatments by Mancozeb and Mefenoxam

Two hundred and fifteen green beans samples from an agricultural region of the Souss (Agadir, Morrocco) were analyzed for endosulfan, dithiocarbamate, bifenthrin, chlorothalonil, iprodion, procymidon and deltamethrin. Of 189 samples that contained pesticide residues, dithiocarbamates (mancozeb and mefenoxam) were detected in 43 (20 %) in the concentration range of 0.045 to 2.651 mg Kg-1. Four o...

متن کامل

Ultra-trace Determination of Palladium(II) by Spectrophotometric Flow Injection Analysis

Nowadays, palladium compounds due to their especial characteristics used in different industries, mainly in electrical power sources and chemical productions as a catalyst. Therefore, Pd concentration is increasing in our around that can be contaminant our environment due its toxic effects. In this work, a simple, selective and rapid flow injection method of analysis (FIA) has been developed fo...

متن کامل

Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine

A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...

متن کامل

Development of Single Walled Carbon Nanotube-Molybdenum Disulfide Nanocomposite/poly-ethylene Glycol Modified Carbon Paste Electrode as an Electrochemical Sensor for the Investigation of Sulfadiazine in Biological Samples

A rapid electrochemical analysis of sulfadiazine (SFZ) has been carried out by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods by employing a sensitive single walled carbon nanotube-molybdenum disulfide nanocomposite/poly ethylene glycol modified carbon paste electrode (SWCNT-MoS2/PEG/CPE). The SFZ shows anodic peak potential at 0.94 V (vs. Ag/AgCl) in 0.1 M PBS of pH 7...

متن کامل

Development and Validation of RP-HPLC-UV Method for Determination of Diclofenac Sodium Residues on Surfaces for Cleaning Validation

In recent years, cleaning validation has achieved a position of increasing in the pharmaceutical industry. It provides assurance to the cleaning procedure that ensures equipment is consistently cleaned from the product, detergent and microbial residues to an acceptable level to avoid cross-contamination and adulteration of drug product with other active ingredients. The aim of this study was to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of agricultural and food chemistry

دوره 47 1  شماره 

صفحات  -

تاریخ انتشار 1999