A New Automatic System Calibration of Multi-cameras and Lidar Sensors
نویسندگان
چکیده
In the last few years, multi-cameras and LIDAR systems draw the attention of the mapping community. They have been deployed on different mobile mapping platforms. The different uses of these platforms, especially the UAVs, offered new applications and developments which require fast and accurate results. The successful calibration of such systems is a key factor to achieve accurate results and for the successful processing of the system measurements especially with the different types of measurements provided by the LIDAR and the cameras. The system calibration aims to estimate the geometric relationships between the different system components. A number of applications require the systems be ready for operation in a short time especially for disasters monitoring applications. Also, many of the present system calibration techniques are constrained with the need of special arrangements in labs for the calibration procedures. In this paper, a new technique for calibration of integrated LIDAR and multi-cameras systems is presented. The new proposed technique offers a calibration solution that overcomes the need for special labs for standard calibration procedures. In the proposed technique, 3D reconstruction of automatically detected and matched image points is used to generate a sparse imagesdriven point cloud then, a registration between the LIDAR generated 3D point cloud and the images-driven 3D point takes place to estimate the geometric relationships between the cameras and the LIDAR.. In the presented technique a simple 3D artificial target is used to simplify the lab requirements for the calibration procedure. The used target is composed of three intersected plates. The choice of such target geometry was to ensure enough conditions for the convergence of registration between the constructed 3D point clouds from the two systems. The achieved results of the proposed approach prove its ability to provide an adequate and fully automated calibration without sophisticated calibration arrangement requirements. The proposed technique introduces high potential for system calibration for many applications especially those with critical logistic and time constraints such as in disaster monitoring applications.
منابع مشابه
Urban Vegetation Recognition Based on the Decision Level Fusion of Hyperspectral and Lidar Data
Introduction: Information about vegetation cover and their health has always been interesting to ecologists due to its importance in terms of habitat, energy production and other important characteristics of plants on the earth planet. Nowadays, developments in remote sensing technologies caused more remotely sensed data accessible to researchers. The combination of these data improves the obje...
متن کاملAutomatic Calibration of Lidar and Camera Images using Normalized Mutual Information
This paper is about automatic calibration of a camera-lidar system. The method presented is designed to be as general as possible allowing it to be used in a large range of systems and applications. The approach uses normalized mutual information to compare camera images with lidar scans of the same area. A camera model that takes into account orientation, location and focal length is used to c...
متن کاملMulti-sensor Systems for Land-based and Airborne Mapping: Technology of the Future?
Technological advancements in positioning/navigation and imaging sensors that occurred during the last decade of the twentieth century, practically redefined the concept of airborne and land-based mapping. The advent of first Mobile Mapping Systems in early 1990s initiated the process of establishing modern, fully digital, virtually ground control-free photogrammetry and mapping. By the end of ...
متن کاملLiDAR-Camera Calibration using 3D-3D Point correspondences
With the advent of autonomous vehicles, LiDAR and cameras have become an indispensable combination of sensors. They both provide rich and complementary data which can be used by various algorithms and machine learning to sense and make vital inferences about the surroundings. We propose a novel pipeline and experimental setup to find accurate rigid-body transformation for extrinsically calibrat...
متن کاملNew approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras
Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...
متن کامل