Breath-hold FSE for Accurate Imaging of Myocardial and Hepatic R2

نویسندگان

  • D. Kim
  • J. H. Jensen
  • E. X. Wu
  • S. S. Sheth
  • G. M. Brittenham
چکیده

Introduction: For patients with transfusional iron overload, improved noninvasive methods for monitoring iron-chelating therapy are needed. MRI provides a means to non-invasively assess tissue iron concentration in both liver and heart by exploiting the paramagnetic effects of iron on the relaxation rates of solvent protons, such as R1, R2, or R2 . At present, the most widely used method is breath-hold R2 * imaging [1], which has been shown to detect myocardial iron deposition [2]. Limitations of this method are (i) sensitivity to non-iron related magnetic field (B0) inhomogeneities which can confound R2 * measurements within the whole heart [3] and liver and (ii) insensitivity to ferritin iron, the storage iron fraction in equilibrium with the low molecular weight cytosolic iron pool accessed by iron-chelating agents [4]. We have developed an alternative method, R2 imaging based on spin echo pulse sequences, which is relatively insensitive to B0 inhomogeneity while providing a measure of RR2, the “reduced R2” that provides a measure of ferritin iron [5]. Compared with gradient echo sequences, spin echo sequences are slower and more sensitive to motion and heart rate variability. Consequently, spin echo sequences for hepatic and myocardial R2 measurement in thalassemia patients are generally performed during free breathing with respiratory gating [6-8], and their low data acquisition efficiency make them impractical for performing both myocardial and hepatic R2 imaging within a clinically acceptable examination time. The purpose of this study was to develop a breath-hold fast spin echo (FSE)[9] sequence for more accurate imaging of myocardial and hepatic R2. Methods: Figure 1 shows schematic diagrams of the navigator-gated Carr-Purcell-Meiboom-Gill (CPMG)[10, 11] and the breath-hold FSE sequences. In CPMG, each spin echo forms an image. In practice, the radio-frequency (RF) field (B1) inhomogeneity produces flip angle error that result in asymmetry of amplitude between odd and even echoes. Note that phase-cycling corrects the flip angle error only for even echoes. Given this fact, the multi-echo FSE with turbo factor (TF) of 2 was designed with centric k-space reordering, such that two successive echoes form an image with the even and odd echoes filling the inner and outer halves of k-space, respectively (Fig. 2). Compared with even echo CPMG, this FSE should provide comparable accuracy with an acceleration factor of 2, which will then be utilized to perform breath-hold imaging. Both the CPMG and FSE sequences were implemented on a 1.5T whole-body MR scanner (Avanto, Siemens) for comparison. Relevant imaging parameters for both CPMG and FSE include: FOV = 340 x 276 mm, matrix = 128 x 78, GRAPPA acceleration factor = 1.8, slice thickness = 10 mm, BW = 500 Hz/pixel, ESP = 5.6 ms, number of images = 10, echo-train duration ~ 120 ms, and double-inversion black-blood preparation pulse. Image acquisition was repeated for two additional different inter-echo spacing (ESP) of 7 (BW = 295 Hz/pixel; number of images =8) and 10 ms (BW = 155 Hz/pixel; number of images =6), respectively, in order to quantify non-monoexponential T2 decay in the presence of soluble (ferritin) and particulate (hemosiderin) iron [5]. To minimize stimulated echoes, the slice thickness of the refocusing pulse was set to three times that of the excitation pulse [12]. Agarose gel phantom containing different concentrations of iron (0, 0.02, 0.04, 0.06, 0.08, and 0.10 mg Fe/ml) were imaged with TR = 1000 ms. The liver and heart of two patients with thalassemia major were imaged. The breath-hold duration of the FSE was 20-22 s, and the scan duration of the navigator-gated CPMG was typically on the order of 5-7 min. The region-of-interest (ROI) was manually drawn for each object. The reduced R2 (RR2), a measure of the true solution relaxation rates and thus able to detect ferritin iron levels independently of hemosiderin iron levels [5], was calculated by non-linear least square fitting of the three sets of nonmonoexponential relaxation curves with different ESPs [13]. The RR2 values of the phantom and subjects were pooled for linear correlation and Bland-Altman analyses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerated Breath-Hold Multi-Echo FSE Pulse Sequence Using Compressed Sensing and Parallel Imaging for T2 Measurement in the Heart

Introduction: Measurement of proton transverse relaxation time (T2) can be used to detect pathological changes in tissue for a variety of clinical applications, including identification of edema and iron overload. The most widely used T2 mapping pulse sequence is the Carr-Purcell-Meiboom-Gill (CPMG) sequence [1,2]. For body MRI, however, a CPMG pulse sequence is typically performed with navigat...

متن کامل

Free breathing myocardial T2 measurements

INTRODUCTION: Quantitative measurements of Magnetic Resonance tissue parameters is a valuable tool for tissue characterisation and functional imaging. For instance, myocardial T2 quantification is used to detect early rejection of heart transplant [1]. These T2 values are usually estimated by performing several black blood FSE sequences with different Echo Times (TE), thus requiring multiple br...

متن کامل

Free-breathing myocardial T2* mapping using GRE-EPI and automatic Non-rigid motion correction

BACKGROUND Measurement of myocardial T2* is becoming widely used in the assessment of patients at risk for cardiac iron overload. The conventional breath-hold, ECG-triggered, segmented, multi-echo gradient echo (MGRE) sequence used for myocardial T2* quantification is very sensitive to respiratory motion and may not be feasible in patients who are unable to breath-hold. We propose a free-breath...

متن کامل

Accelerated Fast Spin-Echo Magnetic Resonance Imaging of the Heart Using a Self-Calibrated Split-Echo Approach

PURPOSE Design, validation and application of an accelerated fast spin-echo (FSE) variant that uses a split-echo approach for self-calibrated parallel imaging. METHODS For self-calibrated, split-echo FSE (SCSE-FSE), extra displacement gradients were incorporated into FSE to decompose odd and even echo groups which were independently phase encoded to derive coil sensitivity maps, and to genera...

متن کامل

Joint myocardial T1 and T2 mapping using a combination of saturation recovery and T2 -preparation.

PURPOSE To develop a heart-rate independent breath-held joint T1 -T2 mapping sequence for accurate simultaneous estimation of coregistered myocardial T1 and T2 maps. METHODS A novel preparation scheme combining both a saturation pulse and T2 -preparation in a single R-R interval is introduced. The time between these two pulses, as well as the duration of the T2 -preparation is varied in each ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008