RF and amplitude-based probe pressure correction for 3D ultrasound.
نویسندگان
چکیده
Anatomical deformation caused by variable probe contact pressure is a significant problem in freehand 3D ultrasound, particularly for high resolution musculoskeletal and breast scans. We have previously published an amplitude-based algorithm for correcting such errors. In this paper, we compare this approach with a novel, elastography-inspired algorithm which works with the higher resolution radio-frequency (RF) signal. The results show that, although the RF-based algorithm is more precise in certain circumstances, both algorithms are able to compensate for probe pressure in 3D ultrasound data. Consequently, freehand 3D ultrasound users who do not have access to the RF signal are still in a position to perform effective probe pressure correction using the readily available video output, as long as this signal is not affected by significant amounts of frame averaging (persistence).
منابع مشابه
Correction of Probe Pressure Artifacts in Freehand 3 D Ultrasound — Initial Results
We present an algorithm which combines non-rigid image-based registration and conventional position sensing to correct probe-pressure-induced registration errors in freehand three-dimensional (3D) ultrasound volumes. The local accuracy of image-based registration enables the accurate freehand acquisition of high resolution (> 15MHz) 3D ultrasound data, opening the way for 3D musculoskeletal exa...
متن کاملCorrection of Probe Pressure Artifacts in Freehand 3 D Ultrasound — Further Results and Convex Probes
An algorithm has been presented in [5] which combines non-rigid image-based registration and conventional position sensing to correct probe-pressure-induced registration errors in free-hand three-dimensional (3D) ultrasound volumes. Visual results indicated that the algorithm increased both the clarity and accuracy of reslices through in vivo volumetric data sets. These initial findings are ver...
متن کاملTracked 3D Ultrasound in Radio-Frequency Liver Ablation
Recent studies have shown that radio frequency (RF) ablation is a simple, safe and potentially effective treatment for selected patients with liver metastases. Despite all recent therapeutic advancements, however, intra-procedural target localization and precise and consistent placement of the tissue ablator device are still unsolved problems. Various imaging modalities, including ultrasound (U...
متن کاملBlood Brain Barrier Disruption by Focused Ultrasound and Microbubbles: A Numerical Study on Mechanical Effects
Introduction: Microbubbles are widely used as contrast agent in diagnostic ultrasound. Recently they have shown good potential for applications in the therapeutic field such as drug delivery to the brain. Recent studies have shown focused ultrasound in conjunction with injected micro-bubbles could temporarily disrupt blood-brain barrier and let therapeutic agents transport into...
متن کاملDesign, Evaluation and Prototyping of a New Robotic Mechanism for Ultrasound Imaging
This paper presents a new robotic mechanism for ultrasound imaging. The device is placed on a patient's body by an operator, and an ultrasound expert controls the motions of the device to obtain ultrasound images. The paper focuses on the robotic mechanism that performs ultrasound imaging. The design of the mechanism is based on two approaches to produce center of motion for an ultrasound probe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasound in medicine & biology
دوره 31 4 شماره
صفحات -
تاریخ انتشار 2005