Bispectral index monitoring may not reliably indicate cerebral ischaemia during awake carotid endarterectomy.

نویسندگان

  • W C Culp
  • M P Kinsky
  • J A Rios
  • A D Mendelow
چکیده

BACKGROUND Intraoperative ischaemia during carotid cross-clamping in patients undergoing carotid endarterectomy (CEA) is a major complication and prompt recognition of insufficient collateral blood supply is crucial. Electroencephalogram (EEG) is believed to be one of the useful forms of monitoring cerebrovascular insufficiency during CEA. The aim of this study was to evaluate the utility of bispectral index (BIS) monitoring, a processed EEG parameter, for the reliable detection of intraoperative cerebral ischaemia during awake CEA. METHODS We monitored 52 patients continuously with the BIS monitor together with assessment of neurological function (contralateral upper and lower limb strength and the verbal component of the Glasgow Coma Scale for speech) in patients undergoing awake CEA. RESULTS Overall mean BIS value in all patients was 96 (SD 2.9). In five patients who showed clinical evidence of cortical ischaemia during carotid cross-clamping, there was no change in the original range of BIS values throughout the procedure (96.7 [3.2]). In one patient BIS values decreased to 38 about 5 min after the incision and recovered within the next 10 min. The mean BIS value in the remaining 46 patients who did not develop clinical signs of ischaemia was 95.4 (2.6). Three cases are presented which demonstrate the inability of the BIS monitor to detect cerebral ischaemia. CONCLUSIONS Lack of correlation of BIS with the signs of cerebral ischaemia during CEA makes it unreliable for detection of cerebrovascular insufficiency. We conclude that awake neurological testing is the preferred method of monitoring in these patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lateralisation of the BIS Sensor during Carotid Endarterectomy Does it Really Matter?

Bispectral index (BIS) monitoring is commonly used to provide a measure of depth during general anaesthesia in attempt to reduce the rare occurrence of awareness [1,2]. The Bispectral Index is a generated number between 0 and 100 that is derived through utilization of a number of advanced EEG signal processing techniques including bispectral analysis, power spectral analysis, and time domain an...

متن کامل

Monitoring cerebral ischemia during carotid endarterectomy and stenting

Current therapy for carotid stenosis mainly includes carotid endarterectomy and endovascular stenting, which may incur procedure-related cerebral ischemia. Several methods have been employed for monitoring cerebral ischemia during surgery, such as awake neurocognitive assessment, electroencephalography, evoked potentials, transcranial Doppler, carotid stump pressure, and near infrared spectrosc...

متن کامل

Bispectral index detects intraoperative cerebral ischaemia during balloon assisted cerebral aneurysm coiling

Bispectral index (BIS) is a monitoring modality designed and used for monitoring depth of anaesthesia. We wish to report a case where BIS monitoring may have alerted us to a potential adverse neurological event during angiographic coiling of a cerebral aneurysm.

متن کامل

Transcranial Doppler detected cerebral microembolism following carotid endarterectomy.

Cerebral ischaemia, the most frequent serious complication of carotid endarterectomy (CEA), usually occurs in the early postoperative period and is often the result of thromboembolism. We hypothesized that the early postoperative detection of microembolic ultrasonic signals (MES) with transcranial Doppler ultrasound (TCD) may be of value in identifying patients at risk of postoperative cerebral...

متن کامل

Cerebral monitoring during carotid endarterectomy--a comparison between electroencephalography, transcranial cerebral oximetry and carotid stump pressure.

OBJECTIVE Various modalities are used for cerebral monitoring during carotid endarterectomy (CEA). The aim of this study was to evaluate whether transcranial cerebral oximetry (TCO) and carotid stump pressure (SP) are as accurate as electroencephalography (EEG) for monitoring cerebral ischaemia during carotid cross-clamping. METHODS One hundred consecutive patients who underwent CEA were stud...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 94 6  شماره 

صفحات  -

تاریخ انتشار 2005