Fault diagnosis of power transformers have always drawn the attention among the users, without removing the transformers from the service. Thus it is necessary to detect the incipient fault of a power transformer at an early stage and diagnose properly on optimum way. Dissolved gas analyses (DGA) is widely used to detect incipient faults in oil filled power transformers. Throughout the world, different countries/utilities are using different techniques/tools to diagnose the faults; such as Key gas ratio, Roger’s gas ratio and Doernenburg gas ratio and Duval Triangle methods, etc. Also different international/national standards are adopted subjected to country’s tropical conditions; ie C.E.G.B. (Central Electricity Generating Board, UK), IEC and IEEE ratio codes and IS standards. Different transformer oil sampling standard practices/procedures are used to minimise the errors and contamination during the whole process of sampling, transportation, preservation and gas extractions at suitable conditions. In this paper, authors have found that Duval Triangle methods’ software implementation ( in MATLABs) for fault interpretations can provide total solution for any kind of fault exist in the power transformers. The whole Duval triangle interpretations are applied on merely three gases methane (CH4), ethane (C2H4) and acetylene (C2H2) after collecting through chromatography. Also for cross verification purposes Duval Triangle’s manual (graphical) interpretation is applied. The results show that Duval Triangle interpretation is a robust and optimum 530 Sukhbir Singh et al technique and does not require much expertise. Software implementation of Duval Triangle also cross verified with other high level languages to emphasise its supremacy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fault Diagnosis of Power Transformer using Duval Triangle Based Artificial Intelligence Techniques

The fault diagnosis of the dissolved gas analysis (DGA) of the power transformer is to be enhanced than previous adopted techniques; this paper proposes a novel adaptive neuro Fuzzy inference system for the incipient fault recognition through enhanced approach. Complying with the practical DGA records and associated fault causes as much as possible, an ANFIS algorithm is presented to establish ...

متن کامل

A new approach of DGA interpretation technique for transformer fault diagnosis

Dissolved Gas Analysis (DGA) is one of the most common techniques to detect the incipient faults in the oil-filled power transformers. In this paper, a new approach of DGA technique is proposed to overcome the conflict that takes place in the traditional interpretation techniques for transformer fault diagnosis. The new approach is based on the analysis of 386 dissolved gas samples data set tha...

متن کامل

Power Transformer Incipient Faults Diagnosis Based on Dissolved Gas Analysis

Incipient fault diagnosis of a power transformer is greatly influenced by the condition assessment of its insulation system oil and/or paper insulation. Dissolved gas-in-oil analysis (DGA) is one of the most powerfull techniques for the detection of incipient fault condition within oil-immersed transformers. The transformer data has been analyzed using key gases, Doernenburg, Roger, IEC and Duv...

متن کامل

A new fuzzy logic approach to identify power transformer criticality using dissolved gas-in-oil analysis

Dissolved gas analysis (DGA) of transformer oil is one of the most effective power transformer condition monitoring tools. There are many interpretation techniques for DGA results however all current techniques rely on personnel experience more than analytical formulation. As a result, the current techniques do not necessarily lead to the same conclusion for the same oil sample. A significant n...

متن کامل

Analysis of Power Transformer using fuzzy expert and neural network system

Power transformers being the major apparatus in a power system, thus the assessment of transformer operating condition and lifespan have obtained crucial significance in latest years. Dissolved gas analysis (DGA) is a sensitive and reliable technique for the detection of incipient fault condition within oil-immersed transformers, which provides the basis of diagnostic evaluation of equipment he...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011