Pelvic tilt measurement before and after total hip arthroplasty.

نویسندگان

  • B Blondel
  • S Parratte
  • P Tropiano
  • V Pauly
  • J-M Aubaniac
  • J-N Argenson
چکیده

INTRODUCTION Most computer-assisted navigation systems used in total hip arthroplasty (THA) reference the anterior pelvic plane, which connects the anterior superior iliac spines and the pubic symphysis. The pelvic tilt is defined as the angle between this anterior pelvic plane (APP) and a vertical line in the standing position. Important interindividual variations of this angle have been reported and may affect final functional anteversion of the acetabular cup. The preoperative value of the pelvic tilt has been included in computer-assisted navigation systems to improve acetabular cup positioning. However, there is no data available which strongly confirms the consistency of this angle for each individual after hip prosthesis implantation. HYPOTHESIS The orientation of the APP in the standing position is not significantly modified after THA. OBJECTIVES To evaluate in a prospective manner, the reproducibility of pelvic tilt measurement and its variability between THA preoperative and 3-year postoperative measurements. MATERIALS AND METHODS A lateral teleradiograph of the pelvis and dorsolumbar spine was obtained in the standing position preoperatively and 3 years after THA. Fifty patients undergoing THA performed by a single operator via an anterolateral approach (26 males and 24 females) were included prospectively. The pelvic tilt was measured on radiographs by two independent observers. The angle was defined as positive in case of pelvis retroversion relative to the vertical plane and negative in case of anteversion. Bland-Altman analysis was used to assess levels of agreement between both operator measurements while preoperative and last follow-up measurements were compared using the Student t-test for unpaired samples. RESULTS The level of agreement between measurements of both operators was satisfactory. Mean preoperative pelvic tilt was 4.68 degrees +/-0.68 S.D. (-6 degrees to 14 degrees), and 4.78 degrees +/-0.64 S.D. (-5 degrees to 14 degrees) at last follow-up. The mean difference between preoperative and last follow-up measurements was 3 degrees +/-0.3 S.D. There was no statistically significant variation between preoperative and 3-year follow-up values (p>0.05). Ninety-five percent of the patients had less than a 5 degrees difference between both measurements while 5% had a difference ranging from 5 degrees to 10 degrees ; none of the patients reported a variation greater than 10 degrees . DISCUSSION Our findings show no significant variation in pelvic tilt between preoperative and 3-year follow-up values after THA. Therefore, the individual preoperative value of this angle should be integrated to achieve proper acetabular cup placement during THA especially when using computed assisted navigation based on the APP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preoperative planning for implant placement with consideration of pelvic tilt in total hip arthroplasty: postoperative efficacy evaluation

BACKGROUND In total hip arthroplasty (THA), tilting of the pelvis alters the cup placement angles. Thus, the cup angles need to be planned with consideration of the effects of pelvic tilt. In the present study, we evaluated the efficacy of preoperative planning for implant placement with consideration of pelvic tilt in THA, and the accuracy of a CT-based computer navigation for implant position...

متن کامل

Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice?

PURPOSE The aim of this prospective study is to validate a vector arithmetic method for measuring acetabular cup orientation after total hip arthroplasty (THA) and to verify the clinical practice. MATERIALS AND METHODS We measured cup anteversion and inclination of 123 patients after cementless primary THA twice by two examiners on AP pelvic radiographs with a vector arithmetic method and com...

متن کامل

Influence of Pelvic Tilt on Polyethylene Wear after Total Hip Arthroplasty

We aimed to evaluate the effects of pelvic tilt on polyethylene wear after total hip arthroplasty (THA). A total of 105 joints treated with primary THA were included; conventional polyethylene (CPE) liners were used in 43 hips and highly cross-linked polyethylene (HXLPE) liners were used in the remaining 62 hips. The pelvis was tilted 6° posteriorly in the standing position as compared to the s...

متن کامل

Late Anterior Dislocation Due to Posterior Pelvic Tilt in Total Hip Arthroplasty

BACKGROUND Excessive pelvic tilt may be one of the factors leading to instability in total hip arthroplasty (THA), even when the acetabular cup is placed properly. To our knowledge, only a few studies have described late anterior dislocation due to posterior pelvic tilt. We present 3 cases with late anterior dislocations possibly due to posterior pelvic tilt. CASES PRESENTATIONS Case-1: An 84...

متن کامل

Correcting for Pelvic Posture Influence on Cup Anteversion Measurements

INTRODUCTION Malposition of the acetabular component is a risk factor for postoperative dislocation after total hip arthroplasty (THA)[1]. Current radiographic techniques for assessing cup anteversion have been developed, but they have limitations[2]. The purpose of this study is to investigate the effect of and reduce the error caused by various pelvis postures on cup anteversion measurement. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopaedics & traumatology, surgery & research : OTSR

دوره 95 8  شماره 

صفحات  -

تاریخ انتشار 2009