Leukopenia, hypoxia, and complement function with different hemodialysis membranes.

نویسندگان

  • A I Jacob
  • G Gavellas
  • R Zarco
  • G Perez
  • J J Bourgoignie
چکیده

Complement activation during exposure of plasma to cuprophan has been postulated to cause leukopenia and hypoxia in hemodialysis patients. To determine if hypoxia is related to leukopenia and if complement activation leads to a depletion of functional complement components, we dialyzed four patients three times sequentially against each of four types of membranes: cuprophan, regenerated cellulose, cellulose acetate, and polyacrilonitrile. Within 20 min there was a marked leukopenia with cuprophan from 5541 +/- 376 to 1216 +/- 94 (P less than 0.001) and with regenerated cellulose from 5541 +/- 411 to 1533 +/- 203 (P less than 0.001). With cellulose acetate, the change from 5558 +/- 400 to 3783 +/- 341 (P less than 0.001) was less dramatic, and with polyacrilonitrile the fall from 5591 +/- 381 to 464 +/- 401 (P less than 0.02) was minimal. After 2 and 4 hours of dialysis, a rebound leukocytosis was seen with cuprophan, regenerated cellulose, and cellulose acetate, but not with polyacrilonitrile. Transient thrombocytopenia occurred with cuprophan and regenerated cellulose. In spite of the variable degree of leukopenia, all membranes induced a similar and significant hypoxia, which was progressive throughout dialysis, even during the rebound leukocytosis. After 4 hours, the mean PO2 ranged from 91 to 93 mm Hg with all membranes. Functional hemolytic titers of whole complement, C3, C5, and C4 were normal prior to hemodialysis and failed to decrease after 4 hours with any membrane. It is concluded that hemodialysis leukopenia is membrane-dependent and is not the cause of hypoxia. In addition, hemodialysis complement activation does not lead to functional complement depletion and is of no clinical significance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodialysis leukopenia and complement function with different dialyzers.

The relationship between leukopenia and the complement system during hemodialysis was re-examined by studying not only the in vivo effects of four different dialyzer membranes (cellulose hydrate, cuprophan, cellulose acetate, and polyacrilonitrile) on leukocyte counts and complement levels, but especially by investigating the effects of these membranes on complement function in vitro. Whereas f...

متن کامل

Dialysis-induced hypoxemia: membrane dependent and membrane independent causes.

Hypoxemia during hemodialysis may result from several differing processes. We initially studied patients undergoing standard acetate hemodialysis. At 15 minutes of dialysis, leukopenia (primarily neutropenia), a decline of platelet count, and hypoxemia occurred, but without a significant change in mean minute ventilation. Complement activation (V/A ratios of C5a greater than 1.0) persisted thro...

متن کامل

Hemodialysis leukopenia. Pulmonary vascular leukostasis resulting from complement activation by dialyzer cellophane membranes.

Acute leukopenia occurs in all patients during the first hour of hemodialysis with cellophanemembrane equipment. This transient cytopenia specifically involves granulocytes and monocytes, cells which share plasma membrane reactivity towards activated complement components. The present studies document that complement is activated during exposure of plasma to dialyzer cellophane, and that upon r...

متن کامل

Relationship between platelet count and hemodialysis membranes

BACKGROUND One factor associated with poor outcomes in hemodialysis patients is exposure to a foreign membrane. Older membranes are very bioincompatible and increase complement activation, cause leukocytosis by activating circulating factors, which sequesters leukocytes in the lungs, and activates platelets. Recently, newer membranes have been developed that were designed to be more biocompatib...

متن کامل

Effects of High-Flux versus Low-Flux Membranes on Pulmonary Function Tests in Hemodialysis Patients

BACKGROUND Several studies have been carried out to evaluate the effects of dialysis on pulmonary function tests (PFT). Dialysis procedure may reduce lung volumes and capacities or cause hypoxia; however, to the best of our knowledge, there is no previous study evaluating the effects of membrane type (high flux vs. low flux) on PFT in these patients. The aim of this study was the evaluation of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kidney international

دوره 18 4  شماره 

صفحات  -

تاریخ انتشار 1980