An investigation of operating theatre staff exposed to humidifier fever antigens.
نویسندگان
چکیده
Sixty staff working in a hospital operating theatre, where a case of humidifier fever had been identified, were studied together with 49 subjects working in other parts of the hospital. They each had a blood test for serology, a skin test, and a chest radiograph and completed a questionnaire. The theatre staff also had pulmonary function tests. The theatre humidifier was found to contain several organisms including amoebae and antigens cross-reacting highly with those implicated in previous outbreaks of humidifier fever. Of the 60 exposed subjects, 25 had developed antibodies, nine had probable symptoms of humidifier fever, and six possible symptoms. There was a strong association between symptoms and antibodies (p = 6 x 10(-5) by Fisher's exact test). The development of antibodies was also related to duration of exposure in the theatre (p less than 0.01 by X2 test for trend) and inversely to smoking (p = 0.0073 by Fisher's exact test) but not to history of atopy. Because of the presence of antigens and because certain biocides added were ineffective in controlling antigenic build-up the humidifier was switched off. Eight months later specific IgG levels in the theatre staff sera, estimated by an enzyme-linked immunosorbent assay technique, had fallen on average by 25%. Inhalation challenge with humidifier water was performed in eight subjects. Four subjects reacted to the challenge, including both those with antibodies and previous symptoms.
منابع مشابه
تأثیر مدیریت کیفیت بر درآمد بخش اعمال جراحی بیمارستان: گزارش کوتاه
Background: Hospitals are dealing with unlimited demands and limited resources. Hospital managers should use appropriate strategies to improve quality of services, enhance patients’ satisfaction and increase financial resources. This study aimed to examine the impact of quality management. Methods: A participatory action research was used for the intervention on income of operating theatre in ...
متن کاملMicrobial and immunological investigations and remedial action after an outbreak of humidifier fever.
Humidifier fever (Monday sickness) occurring in office staff in a factory processing rayon presented as pyrexia with a polyuria and leucocytosis on the first day back to work after a break during the winter half of the year. Chest radiographs showed no abnormalities but pulmonary function tests indicated mild airways obstruction in the affected group as a whole. Respirable dust samples taken on...
متن کاملAn analytic model of membrane humidifier for proton exchange membrane fuel cell
An essential requirement for an operating PEM fuel cell is providing proper water content in the membrane. To avoid water flooding an appropriate water balance is required. Here, an analytic model of a planar membrane humidifier for PEM fuel cell is proposed where the effect of dimensional parameters includes membrane thickness, membrane area and channel hydraulic diameter are investigated. A N...
متن کاملReduction of skin bacteria in theatre air with comfortable, non-woven disposable clothing for operating-theatre staff.
Conventional loose-weave cotton operating garments were compared with clothing of a non-woven fabric to test their efficacy in reducing the dispersal of skin bacteria into theatre air. When men wore operating suits made of the non-woven fabric dispersal of skin bacteria was reduced by 72%. When all the operating-theatre staff wore suits and dresses of this fabric air bacterial counts during ope...
متن کاملLung function of office workers exposed to humidifier fever antigen.
Office workers who became sensitised to antigens derived from humidifier sludge developed episodes of fever, malaise, and other symptoms, including polyuria and mild chest tightness. The episodes usually occurred on a Monday evening and were to some extent dose-related. Lung function was assessed over a day shift on two occasions, including one after which almost all the susceptible subjects de...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of industrial medicine
دوره 38 2 شماره
صفحات -
تاریخ انتشار 1981