Effects of overdenture retention designs and implant orientations on load transfer characteristics.

نویسندگان

  • D R Federick
  • A A Caputo
چکیده

Various approaches have been used for the retention and stabilization of implant-supported overdentures. This study examined photoelastically the simulated load transfer characteristics of a resilient cap attachment with moderately atrophied mandibular plastic models with two implant orientations. Comparison was made with overdentures supported by a splinting bar and a bar with distal resilient cap attachments. Stress patterns developed by simulated occlusal loading demonstrated little cross-arch load sharing and more uniform stress distribution with noninclined implants for all retention designs. The most equitable simulated occlusal force transfer was provided by the resilient cap attachments direct to the implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

Influence of attachment systems on load transfer of an implant-assisted maxillary overdenture.

PURPOSE This photoelastic study compared the load transfer characteristics of 2 retention mechanisms in an implant-assisted overdenture prosthesis. MATERIALS AND METHODS Four implants were incorporated into a photoelastic model of a moderately resorbed edentulous human maxilla. Two retention mechanisms were studied by changing components on the same model and the palateless overdenture. The r...

متن کامل

Retention of maxillary implant overdenture bars of different designs.

STATEMENT OF PROBLEM The specific degree of retention for overdenture attachments is unknown in relation to design, location, and alignment to supporting dental implants. PURPOSE The purpose of this study was to evaluate the initial retention characteristics of 5 implant maxillary overdenture designs under in vitro dislodging forces. MATERIAL AND METHODS A simulated edentulous maxilla was f...

متن کامل

Load Transfer Characteristics of Various Designs of Three-Implant-Retained Mandibular Overdentures.

PURPOSE Many different attachment systems (eg, bars, studs, magnets, telescopic copings) have been used to retain overdentures. The current study aimed to investigate the load transfer characteristics and to compare the stress levels of four attachment designs for mandibular overdentures retained by one central implant and two inclined distal implants. MATERIALS AND METHODS Photoelastic mandi...

متن کامل

Evaluation of Strain Distribution in Bone around Implant in Treatment Design of Overdentures Using Computer and Modeling of Finite Elements

Introduction: Introduction: Few studies have investigated the distribution of stress around implants. In this study the distribution of stress in bones around implants was investigated in five overdenture (OD) treatment designs including OD-1, OD-2, OD-3, OD-4 and OD-5. Materials and methods: The Catia modeling software was used in order to simulate the tooth/implant model and bone. First, the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 76 6  شماره 

صفحات  -

تاریخ انتشار 1996