On-chip contactless four-electrode conductivity detection for capillary electrophoresis devices.
نویسندگان
چکیده
In this contribution, a capillary electrophoresis microdevice with an integrated on-chip contactless four-electrode conductivity detector is presented. A 6-cm-long, 70-microm-wide, and 20-microm-deep channel was etched in a glass substrate that was bonded to a second glass substrate in order to form a sealed channel. Four contactless electrodes (metal electrodes covered by 30-nm silicon carbide) were deposited and patterned on the second glass substrate for on-chip conductivity detection. Contactless conductivity detection was performed in either a two- or a four-electrode configuration. Experimental results confirmed the improved characteristics of the four-electrode configuration over the classical two-electrode detection setup. The four-electrode configuration allows for sensitive detection for varying carrier-electrolyte background conductivity without the need for adjustment of the measurement frequency. Reproducible electrophoretic separations of three inorganic cations (K+, Na+, Li+) and six organic acids are presented. Detection as low as 5 microM for potassium was demonstrated.
منابع مشابه
Contactless conductivity detector for microchip capillary electrophoresis.
A microfabricated electrophoresis chip with an integrated contactless conductivity detection system is described. The new contactless conductivity microchip detector is based on placing two planar sensing aluminum film electrodes on the outer side of a poly(methyl methacrylate) (PMMA) microchip (without contacting the solution) and measuring the impedance of the solution in the separation chann...
متن کاملPortable CE-system with contactless conductivity detection in an injection molded polymer chip for on-site food analysis
We present a compact portable chip-based capillary electrophoresis system that employs capacitively coupled contactless conductivity detection (CD) operating at 4 MHz as an alternative detection method compared to the commonly used optical detection employing laser-induced fluorescence. The disposable chip for this system is fabricated out of PMMA using injection molding; the electrodes are scr...
متن کاملContactless Conductivity Detection in Ceramic Technology for On-Chip Electrophoresis
A capacitively coupled contactless conductivity detector produced in Low Temperature Co-fired Ceramic (LTCC) technology for microchip capillary electrophoresis (CE) is reported in this work. Electrodes located outside the measurement channel are used to sense impedance variations caused by conductive ions. The application of LTCC in combination with contactless conductivity detection is very pr...
متن کاملDual contactless conductivity and amperometric detection on hybrid PDMS/glass electrophoresis microchips.
A new approach for the integration of dual contactless conductivity and amperometric detection with an electrophoresis microchip system is presented. The PDMS layer with the embedded channels was reversibly sealed to a thin glass substrate (400 microm), on top of which a palladium electrode had been previously fabricated enabling end-channel amperometric detection. The thin glass substrate serv...
متن کاملA chip-based capillary electrophoresis-contactless conductivity microsystem for fast measurements of low-explosive ionic components.
A miniaturized analytical system for separating and detecting inorganic explosive residues, based on the coupling of a micromachined capillary electrophoresis (CE) chip with a contactless conductivity detector is described. The low electroosmotic flow (EOF) of the poly(methylmethacrylate) (PMMA) chip material facilitates the rapid switching between analyses of cations and anions using the same ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 75 2 شماره
صفحات -
تاریخ انتشار 2003