List-mode reconstruction in 2D strip PET
نویسندگان
چکیده
Using a theory of list-mode maximum likelihood expectation-maximization (MLEM) algorithm, in this contribution, we present a derivation of the system response kernel for a novel positron emission tomography (PET) detector based on plastic scintillators.
منابع مشابه
Projector Model for Efficient List-Mode Reconstruction in PET Scanners with Planar Detectors
Abstrcwt-We have developed a new projector model speciflcally tailored for fast list-mode tomographic reconstructions in Positrón emission tomography (PET) scanners with parallel planar detectors. The model provides an accurate estimation of the probability distribution of coincidence events defined by pairs of scintillating crystals. This distribution is parameterized with 2D elliptical Gaussi...
متن کاملList-Mode Affine Rebinning for Respiratory Motion Correction in PET Cardiac Imaging
Positron Emission Tomography (PET) is an established functional imaging modality but its practical deployment is hampered by motion artefacts. This paper proposes a method for correcting reconstructed PET images through a list-mode rebinning process. Respiratory motion is compensated for by applying 2D affine transforms to the respiratory gated sequence of line-ofresponse events prior to image ...
متن کاملFully 3-D List-mode Positron Emission Tomography Image Reconstruction on a Multi-GPU Cluster
List-mode processing is an efficient way of dealing with the sparse nature of PET data sets, and is the processing method of choice for time-of-flight (ToF) PET. We present a novel method of computing line projection operations required for list-mode ordered subsets expectation maximization (OSEM) for fully 3-D PET image reconstruction on a graphics processing unit (GPU) using the compute unifi...
متن کاملInitial evaluation of a practical PET respiratory motion correction method in clinical simultaneous PET/MRI
University College London, London, UK Respiratory motion during PET acquisitions can cause image artefacts, with sharpness and tracer quantification adversely affected due to count ‘smearing’. Motion correction by registration of PET gates becomes increasingly difficult with shorter scan times and less counts. The advent of simultaneous PET/MRI scanners allows the use of high spatial resolution...
متن کاملPerformance of list mode data acquisition with ECAT EXACT HR and ECAT EXACT HR+ positron emission scanners.
Recently, list mode (event-by-event) data acquisition with positron emission tomography (PET) has been widely noticed because list mode acquisition is superior to conventional frame mode data acquisition in terms of (1) higher efficiency of data storage, (2) higher temporal resolution, and (3) higher flexibility of data manipulation. The aim of this study is to investigate the performance of li...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Bio-Algorithms and Med-Systems
دوره 10 شماره
صفحات -
تاریخ انتشار 2014