Breast-specific gamma imaging is a cost effective and efficacious imaging modality when compared with MRI.

نویسندگان

  • Nathalie Johnson
  • Leslie Sorenson
  • Laura Bennetts
  • Karen Winter
  • Sally Bryn
  • William Johnson
  • Margie Glissmeyer
  • Jennifer Garreau
  • Deb Blanchard
چکیده

BACKGROUND Both MRI and breast-specific gamma imaging are tools for surgical planning in newly diagnosed breast cancer. Breast-specific gamma imaging (BSGI) is used less frequently although it is of similar utility and lower cost. We compared the diagnostic and cost efficacy of BSGI with MRI. METHODS Retrospective review of 1,480 BSGIs was performed in a community breast health center, 539 had a new diagnosis of cancer, 75 patients having both MRI and BSGI performed within 2 months of each other. Institutional charges for BSGI ($850) and MRI ($3,381) were noted. RESULTS BSGI had a sensitivity of 92%, specificity of 73%, positive predictive value of 78%, and negative predictive value of 90%. This compared favorably with MRI that had sensitivity of 89%, specificity 54%, positive predictive value 67%, and negative predictive value 83%. The accuracy of BSGI was higher at 82% vs MRI at 72%. Total cost of MRI imaging was $253,575 vs BSGI at $63,750. CONCLUSIONS BSGI is a cost-effective and accurate imaging study for further evaluation of dense breast tissue and new diagnosis of cancer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

BSGI in Clinical Use: A Summary of Potential Utility, Impact on Early Cancer Detection and Cost Savings

Breast Specific Gamma Imaging (BSGI) is scintimammography performed with breast optimized detectors and has been found to be a cost-effective, highly sensitive and specific breast imaging procedure. Therefore, several authors have proposed various applications for this modality as an adjunctive procedure to mammography and other applications (1,2). The purpose of this summary is to propose the ...

متن کامل

O-19: A Comparison of Pelvic Magnetic Resonance Imaging, Trans-Vaginal and Trans-Rectal Sonography with Laparoscopic Findings in The Diagnosis of Deep Infiltrating Endometriosis

Background The performance of TVS, TRS and MRI for the diagnosis of DIE have been separately reported in earlier studies. However, the three methods have not been concurrently compared in terms of their overall performance and classified results as per different anatomical locations of DIE lesions in a large study population. This study was an attempt to compare pelvic magnetic resonance imagin...

متن کامل

In vitro Study of SPIONs-C595 as Molecular Imaging Probe for Specific Breast Cancer (MCF-7) Cells Detection

Background: Magnetic resonance imaging (MRI) plays an essential role in molecular imaging by delivering the contrast agent into targeted cancer cells. The aim of this study was to evaluate the C595 monoclonal antibody-conjugated superparamagnetic iron oxide nanoparticles (SPIONs-C595) for the detection of breast cancer cell (MCF-7). Methods: The conjugation of monoclonal antibody and nanopartic...

متن کامل

Cumulative radiation exposure dose of diagnostic imaging studies in breast cancer patients

Background: Breast cancer is a common disease in radiation oncology. We evaluated the radiation dose received by breast cancer patients, an often-neglected concern. Materials and Methods: The total effective radiation dose in 101 breast cancer patients was calculated by summing the effective doses of individual diagnostic imaging tests from the first hospital visit to the initiation of radiothe...

متن کامل

Breast cancer imaging: a new role of Tc-99m sestamibi prone scintimammography for diagnosisof breast cancer

Mammography remians the procedure of choice in screening asymptomatic women for breast cancer. However, in patients with symptoms, other types of imaging play an important role in the detection of malignancies. The high cost and lack of availability of PET and MRI largely precludes the use in this patient population. TI-201 is nbt the imaging agent of choice because of its wash-out and redistri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of surgery

دوره 207 5  شماره 

صفحات  -

تاریخ انتشار 2014