The Platelet Function Analyzer (PFA-100) as a Screening Tool in Neurosurgery
نویسندگان
چکیده
We investigated whether the inclusion of the PFA-100 in the preoperative screening of neurosurgical patients might reduce perioperative bleeding complications. Patients with intracranial space-occupying lesions who were scheduled for neurosurgery underwent routine preoperative PFA-100 testing. In case of an abnormal PFA test, patients received prophylactic treatment with desmopressin. 93 consecutive patients were compared to 102 consecutive patients with comparable characteristics operated before introduction of the PFA-100 testing. 2 patients (2.2%) in the PFA group and 2 patients (2.0%) in the non-PFA group experienced clinically relevant intracranial bleeding confirmed by computed tomography (OR 1.05, 95% CI 0.39-2.82; P = 1.0). Transfusions were not significantly different between the two groups. 13 (14.0%) patients in the PFA group and 5 (4.9%) patients in the non-PFA group received desmopressin (OR 3.2, 95% CI 1.1-9.2; P = 0.045). Preoperative screening with the PFA-100 did result in a significant increase in the administration of desmopressin, which could not reduce perioperative bleeding complications or transfusions.
منابع مشابه
Platelet function analyzer (PFA)-100 closure time in the evaluation of platelet disorders and platelet function: a rebuttal.
BACKGROUND Closure time (CT), measured by platelet function analyzer (PFA-100) device, is now available to the clinical laboratory as a possible alternative or supplement to the bleeding time test. AIM On behalf of the Platelet Physiology Subcommittee of the Scientific and Standardization Committee of the International Society on Thrombosis and Haemostasis (ISTH-SSC), a working Group was form...
متن کاملClinical utility of the PFA-100.
The PFA-100 (platelet function analyzer) is a relatively new tool for the investigation of primary hemostasis. This article reviews the history of the PFA-100 and details its clinical utility in several settings. The PFA-100 was first introduced to us in 1995 in an issue of Seminars in Thrombosis And Hemostasis, which included data from a field trial headed by Dr. Eberhard Mammen. Since that ti...
متن کاملScreening for von Willebrand disease with a new analyzer using high shear stress: a study of 60 cases.
We have evaluated the performance of a new analyzer using high shear stress, the PFA-100 (Platelet Function Analyzer, Dade International, Massy, France), for screening of patients with von Willebrand disease (vWD). Whole citrated blood is aspirated through a capillary to the central aperture of a membrane coated with collagen and with a platelet agonist (either epinephrine or adenosine diphosph...
متن کاملEvaluation of the platelet function analyzer (PFA-100) vs. the thromboelastogram (TEG) in the parturient.
BACKGROUND The platelet function analyzer (PFA-100) is a bedside test of coagulation designed to evaluate platelet function. It measures the time required for whole blood to occlude a membrane impregnated with either epinephrine (EPI) or adenosine 5'diphosphate (ADP). The results are reported as closure time (CT-EPI or CT-ADP) in seconds. The thromboelastogram (TEG) measures whole blood clottin...
متن کاملAssessment of thrombocytopenic disorders using the Platelet Function Analyzer (PFA-100).
The Platelet Function Analyzer (PFA-100) was used to measure platelet function in paediatric patients with destructive versus underproduction thrombocytopenia. Closure time (CT) and total volume (TV) measurements with standard 150 microm apertures discriminated between patients with similar platelet counts from 30 to 150 x 10(9)/l. However, at platelet counts < 30 x 10(9)/l, a 100-microm apertu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012