0.5 billion events per second time correlated single photon counting using CMOS SPAD arrays.

نویسندگان

  • Nikola Krstajić
  • Simon Poland
  • James Levitt
  • Richard Walker
  • Ahmet Erdogan
  • Simon Ameer-Beg
  • Robert K Henderson
چکیده

We present a digital architecture for fast acquisition of time correlated single photon counting (TCSPC) events from a 32×32 complementary metal oxide semiconductor (CMOS) single photon avalanche detector (SPAD) array (Megaframe) to the computer memory. Custom firmware was written to transmit event codes from 1024-TCSPC-enabled pixels for fast transfer of TCSPC events. Our 1024-channel TCSPC system is capable of acquiring up to 0.5×10(9) TCSPC events per second with 16 histogram bins spanning a 14 ns width. Other options include 320×10(6) TCSPC events per second with 256 histogram bins spanning either a 14 or 56 ns time window. We present a wide-field fluorescence microscopy setup demonstrating fast fluorescence lifetime data acquisition. To the best of our knowledge, this is the fastest direct TCSPC transfer from a single photon counting device to the computer to date.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Large Area CMOS SPADs with very low Dark Counting Rate

We designed and characterized Silicon Single-Photon Avalanche Diodes (SPADs) fabricated in a high-voltage 0.35 μm CMOS technology, achieving state-of-the-art low Dark Counting Rate (DCR), very large diameter, and extended Photon Detection Efficiency (PDE) in the Near Ultraviolet. So far, different groups fabricated CMOS SPADs in scaled technologies, but with many drawbacks in active area dimens...

متن کامل

9.8μm SPAD-based Analogue Single Photon Counting Pixel with Bias Controlled Sensitivity

A scalable NMOS-only 11T SPAD-based analogue single photon counting pixel is presented. Implemented in advanced 130nm imaging low voltage CMOS, with no extra implants, a state of the art 9.8μm pitch is achieved. Novel pixel operation using a charge transfer amplifier (CTA) allows bias controlled sensitivity from 13.1mV/event to 150μV/event. Less than 2% PRNU is measured in the sensitivity range...

متن کامل

Compact SPAD-Based Pixel Architectures for Time-Resolved Image Sensors

This paper reviews the state of the art of single-photon avalanche diode (SPAD) image sensors for time-resolved imaging. The focus of the paper is on pixel architectures featuring small pixel size (<25 μm) and high fill factor (>20%) as a key enabling technology for the successful implementation of high spatial resolution SPAD-based image sensors. A summary of the main CMOS SPAD implementations...

متن کامل

Time-Correlated Fluorescence Microscopy Using a Room Temperature Solid-State Single Photon Sensor

In this paper we present a two-photon fluorescence lifetime imaging microscopy (FLIM) system based on a two-dimensional single photon avalanche diode (SPAD) array fabricated in CMOS [1] [2]. To the best of our knowledge, this is the first demonstration of two-photon FLIM based on a CMOS detector. The sensor reported here exhibits picosecond accuracy, operates at room temperature, and requires n...

متن کامل

Dynamic Quenching for Single Photon Avalanche Diode Arrays

We propose the use of dynamic circuits for quenching avalanche events in single photon avalanche diode (SPAD) arrays. Two area-efficient, circuit solutions are presented in 0.35μm CMOS technology. These circuits contain no passive elements and consume shoot-through current only at triggering instants. The resulting reduction in power consumption and supply noise is essential to formation of lar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 40 18  شماره 

صفحات  -

تاریخ انتشار 2015