Ocular biometric measurements in cataract surgery candidates in Portugal

نویسندگان

  • Tiago B Ferreira
  • Kenneth J Hoffer
  • Filomena Ribeiro
  • Paulo Ribeiro
  • João G O'Neill
چکیده

OBJECTIVE Describe the ocular biometric parameters and their associations in a population of cataract surgery candidates. METHODS A cross-sectional study of 13,012 eyes of 6,506 patients was performed. Biometric parameters of the eyes were measured by optical low-coherence reflectometry. The axial length (AL), mean keratometry (K) and astigmatism, anterior chamber depth (ACD) (epithelium to lens), lens thickness (LT), and Corneal Diameter (CD) were evaluated. RESULTS The mean age was 69 ± 10 years (44-99 years). Mean AL, Km, and ACD were 23.87 ± 1.55 mm (19.8-31.92 mm), 43.91 ± 1.71 D (40.61-51.14 D), and 3.25 ± 0.44 mm (2.04-5.28 mm), respectively. The mean LT was 4.32 ± 0.49 mm (2.73-5.77 mm) and the mean CD was 12.02 ± 0.46 mm (10.50-14.15 mm). The mean corneal astigmatism was 1.08 ± 0.84 D (0.00-7.58 D) and 43.5% of eyes had astigmatism ≥ 1.00 D. Male patients had longer AL and ACDs (p < .001) and flatter corneas (p < .001). In regression models considering age, gender, Km, ACD, LT, and CD, a longer AL was associated with being male and having higher ACD, LT and CD. CONCLUSIONS These data represent normative biometric values for the Portuguese population. The greatest predictor of ocular biometrics was gender. There was no significant correlation between age and AL, ACD, or Km. These results may be relevant in the evaluation of refractive error and in the calculation of intraocular lens power.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of ketorolac and naphazoline-antazoline eye drops on ocular complaints after cataract surgery

Background: Cataracts are the leading diseases that cause blindness. Cataracts can be treated with surgery. Pain, itching, burning, and a foreign body sensation in the eye are common ocular complaints of patients in recovery. In this study, we compared the effect of Ketorolac eye drops and naphazoline antazoline eye drops on reducing complaints of surgery. Methods: This randomized clinical tri...

متن کامل

Cataract Surgery Feature Story

NOVEMBER/DECEMBER 2012 CATARACT & REFRACTIVE SURGERY TODAY EUROPE 1 A ccuracy of biometric calculations and, more important, of refractive results depends on three main factors: preoperative biometric data including axial length, anterior chamber depth, lens thickness, and corneal curvature power variables; power calculation formulas; and quality and accuracy of the IOL. In the past 15 years, s...

متن کامل

مقایسه قطره دیکلوفناک سدیم با قطره بتامتازون در پیشگیری از ادم سیستویید ماکولا، پس از جراحی کاتاراکت به روش خارج کپسولی با لنز گذاری

Background and purpose: Since Çystoid Macular Ëdema (ÇMË) is caused by ocular inflammation after cataract surgery. Ït’s control with suitable medication is reasonable. Âim of this study was to compare a nonsteroidal topical solution (0.1 % diclofenac) to a steroidal topical solution (0.1 % betamethasone) in preventing ÇMË after extra capsular cataract surgery. Materials and methods: Â pro...

متن کامل

Ocular Ultrasonographic Features in Iranian Native Donkey

Objective- The aim of this study was to evaluate ultrasonographic appearance of the normal eye and obtaining reference values of ocular structures in Iranian native donkey. Design- Experimental study. Animals- Five Iranian native donkeys. Procedures- After preparation of the animals, ocular structures were ima...

متن کامل

B-scan ultrasonography of ocular abnormalities: a review of 182 dogs

Ultrasonography is the only practical method for obtaining images of the posterior segment of the eye when the light-conducting media are opaque. In this study, 182 dogs with ocular abnormalities presented to the Department of Veterinary Surgery and Radiology from December 2008-August 2010 were included. All the animals were subjected to detailed ophthalmic examination and B-scan ultrasonograph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017