Simplified Approach to Repair Early Pseudoaneurysm of the Left Coronary Button Following Composite Graft Because of Acute Type A Aortic Dissection

نویسندگان

  • Thierry Carrel
  • Samuel Hurni
چکیده

We present a simplified surgical technique performed in a 37-yr old man who presented with a pseudoaneurysm of the left coronary ostium 2 months after repair of acute type A aortic dissection by composite graft. Intraoperatively, the surgical situs showed extreme adhesions. The leakage at the level of the coronary suture line was exposed from inside the aortic graft. Repair was performed by 7.0 polypropylene sutures and the postoperative course was uneventful. The patient was discharged on postoperative day 6.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful Repair of Type a Aortic Dissection in a Term Pregnancy: A Case Report

Stanford type A acute aortic dissection (AAD) is a very rare complication, with potentially lethal consequences in pregnancy. In fact, pregnancy has been regularly associated with the possibility of aortic. dissection in almost half of young women. Herein, we present the case of a 38-year-old woman in her 37th week of pregnancy. The patient’s medical history was indicative of G4L2Ab1(4 gestaiti...

متن کامل

سودوآنوریسم فیستولیزه شده فیبروز بین دریچه ای میترال و آئورت در یک بیمار پس از عمل جراحی بای پس عروق کرونر

Pseudoaneurysm is a rare condition in the region of the fibrous body between the mitral and aortic valve, the mitral-aortic intervalvular fibrosa (MAIVF), that has been reported as a sequela of endocarditis and surgical trauma. MAIVF rarely occurs on native aortic valve after infective endocarditis (IE). It is often fatal because of its rapid progress, high rates of rupture and recurrence, and ...

متن کامل

Devastating late complication for repair of type A acute aortic dissection with usage of gelatin-resorcinol-formalin glue.

OBJECTIVES We review cases of pseudoaneurysm formation of the graft anastomosis sites following repair of type A acute aortic dissection by our original leak-proof technique for dissected aortic wall reinforcement with xenopericardium and gelatin-resorcinol-formalin (GRF) glue. CASES A 47-year-old male presented inferior acute myocardial infarction with bradycardia and cardiogenic shock 34 mo...

متن کامل

Aortic Pseudo aneurysm 3 Years after Interposition Tube Graft for Acute Dissection of Ascending Aorta

Introduction: Patients with primary acute aortic dissection are at higher risk of complications, including increasing aortic aneurysm diameter, aortic rupture, aortic pseudo aneurysm, and recurrent aortic dissection. Case presentation We presented the case of a recurrent pseudo aneurysm and rupture of the aorta in the distal a...

متن کامل

Late lumen loss in thoracic aortic end graft after endovascular procedure of a traumatic pseudoaneurysm

We report the case of a 23-year-old woman who died due to endograft stenosis 20 months after thoracic endovascular aortic repair. The patient presented with the pseudocoarctation syndrome. Although angioplasty of stenosis endograft was successfully performed, severe metabolic complications were lethal.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016