Discontinuous electrophoresis on polyacrylamide gel slab.

نویسنده

  • D M Abadi
چکیده

D ISCOT1XUOUS ELECT1IO1’HORESIS in polyacrylamide rods has been used for separation of serum proteins (1). In spite of satisfactory resolution in tile rod, the technic renhains cumbersome, and comparison of the closely migrating cOnlpoflents inaccurate. Akroyd (2) reported discontinuous electrophoresis On polyacrylamide gel slab, which alleviates many of the difficulties of the rod. We llave considerably modified and simplified the electrophoresis on a gel slab so that many samples can be easily processed in one day with a resolution equal to that obtained in polyacrylamide rod. Materials and Methods Reagents and Apparatus

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biochemical Identification of the Two Races of Radopholus similis by Polyacrylamide Gel Electrophoresis.

Analysis of proteins of the banana and citrus race of Radopholus similis was carried out by several different types of polyacrylamide gel electrophoresis. These included standard slab gel, SDS slab gel, gradient slab gel, and two-ditnensional slab gel electrophoresis. A major band difference was detected between the two races by slab gel electrophoresis. However, several other poorly resolved b...

متن کامل

Sodium dodecyl sulfate polyacrylamide slab gel electrophoresis and hydroxyethyl cellurose gel capillary electrophoresis of luminescent lanthanide chelate-labeled proteins with time-resolved detection.

Proteins labeled with a luminescent lanthanide chelate, {{2,2',2'',2'''-{4'-{[(4,6-dichloro-1,3,5-triazin-2-yl)amino]biphenyl-4-yl}-2,2':6',2''-terpyridine-6,6''-diyl}bis(methylenenitrilo)}tetrakis(acetato)}europium(III) (DTBTA-Eu(3+)),were analyzed with sodium dodecyl sulfate-polyacrylamide gel (SDS-PAGE) slab gel electrophoresis and hydroxyethyl cellurose gel capillary electrophoresis with a ...

متن کامل

Resolution of bacterial proteins by polyacrylamide gel electrophoresis on slabs. Membrane, soluble, and periplasmic fractions.

The application of a method of electrophoretic protein analysis to the investigation of the total protein composition of Salmonella typhimurium is described. It involves electrophoresis of many samples simultaneously on a thin slab of acrylamide gel, in the presence of sodium dodecyl sulfate, with the discontinuous buffer system of Laemmli ((19’70) Nature 227, 680485). Up to about 25 samples ca...

متن کامل

Useful buffer and gel systems for polyacrylamide gel electrophoresis.

Seven buffer and gel systems for polyacrylamide gel electrophoresis using discontinuous voltage and pH gradients (disc electrophoresis according to ORNSTEIN-UAVIS) and five systems using discontinuous voltage gradients at constant pH (according to ALLEN) have been compiled and characterized. Usefulness and applicability of the systems for clinical investigations are discussed and illustrated by...

متن کامل

Sodium dodecyl sulfate-glycerol polyacrylamide slab gel electrophoresis for the resolution of apolipoproteins.

We describe the resolution of the plasma apolipoproteins with molecular weights from 8,800 to greater than 550,000, using a 3.5% sodium dodecyl sulfate-glycerol polyacrylamide slab gel system. The simplicity of this system and the resolution of proteins over a broad range of molecular weights will make it particularly useful in investigations of apolipoprotein composition of plasma lipoproteins.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 15 1  شماره 

صفحات  -

تاریخ انتشار 1969