Behaviour of anisotropic conductive joints under mechanical loading
نویسندگان
چکیده
Anisotropic conductive films (ACFs) received a great deal of attention in recent years for interconnection applications in electronic packaging. This paper reports the behaviour of ACF joints under various mechanical loading, i.e., die shear and cyclic fatigue in shear. The mechanical behaviour of ACF joints that have been exposed to environmental effects, i.e., high moisture and elevated temperature (autoclave test conditions) has been examined using die shear test. The maximum shear force prior to fracture was determined as 465.0 N, at which the contact resistance is found extremely high and can be considered as open circuits. Epoxy based ACF exhibits insignificant plastic deformation, especially for samples that have undergone autoclave test. Reduction trend was observed in the shear moduli over autoclave test time for ACF joints. Fracture surface of ACF that failed in shear test shows spalling and less plastic deformation after exposed to autoclave test. For cyclic fatigue test, the endurance limit is determined at about 143.5 N and the corresponding calculated endurance ratio is around 32.0%. 2002 Elsevier Science Ltd. All rights reserved.
منابع مشابه
Study of anisotropic conductive adhesive joint behavior under 3-point bending
Flip chip interconnections using anisotropic conductive film (ACF) are now a very attractive technique for electronic packaging assembly. Although ACF is environmentally friendly, many factors may influence the reliability of the final ACF joint. External mechanical loading is one of these factors. Finite element analysis (FEA) was carried out to understand the effect of mechanical loading on t...
متن کاملFatigue Life of Repaired Welded Tubular Joints
In this study, the effect of repair on fatigue life of tubular joints is investigated. Six cracked specimens precedently subjected to fatigue loading undergone to weld repair. Two of those specimens were shot peened before primary fatigue loading. It is shown that repair gives rise to about 150% increase in fatigue life for original specimens while the increase of fatigue life for shot-peened ...
متن کاملEffect of autoclave test on anisotropic conductive joints
This paper reports that the stress-corrosion cracking induced by autoclave test condition reduces the mechanical strength of anisotropic conductive joints and also increases the contact resistance by allowing more moisture to reach the aluminium metallization. The use of anisotropic conductive joints with bumpless chips allows a reduction in the costs of the flip chip bonding process. The epoxy...
متن کاملFailure Procedure in Adhesive Composite Joints under Different Types of Loading
In this paper, we have used numerical simulation to study failure of adhesive joints in composite plates. To determine the failure load, adhesive joints are subjected to different types of loading and gradual failure of the joint is studied using the finite element method. The composite material failure theory is implemented into the FEM software. Also different geometries for the joint edge ar...
متن کاملClarification of the mechanical behaviour of spinal motion segments through a three-dimensional poroelastic mixed finite element model.
The purpose of this study is to clarify the mechanical behaviour of spinal motion segments through a proper numerical model. The model constructed can give correct information and provide medical fields with valuable guidance in solving clinical problems occurring in the spine. A three-dimensional poroelastic finite element model of spinal motion segments is constructed and a mixed formulation ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Microelectronics Reliability
دوره 43 شماره
صفحات -
تاریخ انتشار 2003