Breathing motion artifact reduction for MRI with continuously moving table using motion consistent retrospective data selec- tion
نویسندگان
چکیده
Introduction: In MRI with continuously moving table (CMT-MRI) the compensation of breathing motion is a difficult problem. Existing breathing motion compensation techniques for CMT-MRI are either limited to TSE-based sequences where motion consistent snapshots are acquired with one single echo train [1,2], or they apply respiratory gating [3]. The latter approach can fail, however, if the true gating efficiency is lower than estimated a priori, resulting in an insufficient amount of data which can be acquired for the desired region due to the continuous table motion. In this work a novel breathing motion compensation approach for CMT-MRI is proposed. It acquires data redundantly during the whole breathing cycle and retrospectively extracts motion consistent undersampled k-spaces for parallel imaging reconstruction from that data. This approach is particularly suitable for acquisition schemes where the rapid sampling of motion consistent snapshots is not possible.
منابع مشابه
Accelerated free breathing MRI with continously moving table using compressed sensing
Introduction In MRI with continuously moving table (CMT) breathing motion is an important issue. Recently motion compensation techniques for CMT-MRI during free breathing have been introduced [1, 2]. They apply parallel imaging to reconstruct multiple snapshots of the breathing motion from a fully sampled k-space and combine these snapshots subsequently. In this study the compressed sensing (CS...
متن کاملRespiratory-Gated Continuously Moving Table 3D MRI
B. Aldefeld, P. Börnert, J. Keupp, K. Nehrke Philips Research Laboratories, Hamburg, Germany Introduction When continuously moving table imaging is applied to an extended virtual FOV that includes the abdomen and chest, the physiological motion of the patient must be addressed to achieve optimum image quality. Scanning under breath-hold conditions is unacceptable in most cases because scan time...
متن کاملUltrasound echoes as biometric navigators.
We demonstrate a new method of using ultrasound data to achieve prospective motion compensation in MRI, especially for respiratory motion during interventional MRI procedures in moving organs such as the liver. The method relies on fingerprint-like biometrically distinct ultrasound echo patterns produced by different locations in tissue, which are collated with geometrical information from MRI ...
متن کاملMR compatible sensor for motion artifact corrected reconstruction method
INTRODUCTION: Patient motion, especially respiratory and cardiac motion, leads to artifacts which could damage the quality of Magnetic Resonance Imaging (MRI) and make the resulting diagnosis less accurate. If such motion occurs during MRI acquisitions, it has been shown that, knowing this motion, it is possible to invert the process of artifact production and to reconstruct a motion compensate...
متن کاملMotion Estimated-Compensated Reconstruction with Preserved-Features in Free-Breathing Cardiac MRI
To develop an efficient motion-compensated reconstruction technique for free-breathing cardiac magnetic resonance imaging (MRI) that allows high-quality images to be reconstructed from multiple undersampled single-shot acquisitions. The proposed method is a joint image reconstruction and motion correction meth-od consisting of several steps, including a non-rigid motion extraction and a motion-...