Portable pupillography of the swinging flashlight test to detect afferent pupillary defects.
نویسندگان
چکیده
OBJECTIVE To investigate the ability of a portable, personal computer-driven, pupillometer to record the pupillary response curve during the swinging flashlight test. Also, to determine whether these response curves can be used to identify and quantify relative asymmetry in the pupillary light reflex between eyes in healthy volunteers with simulated afferent pupil defects (APDs) and patients with optic neuropathies. DESIGN Comparative, observational case series and instrument validation. PARTICIPANTS Healthy volunteers with no known ocular disease and patients (n = 20) with various optic neuropathies noted to have relative APDs on examination. METHODS Pupillary response curves of the right eye were recorded with a portable, electronic, infrared pupillometer from healthy volunteers (with and without simulated APDs) and patients with APDs while the light stimulus alternated between eyes, simulating the swinging flashlight test. Simulated APDs in healthy volunteers were created with increasingly dense neutral density filters in front of the left eye. MAIN OUTCOME MEASURES Differences in constriction amplitude, latency, and constriction velocity of the pupillary response with right eye stimulation versus left eye stimulation in both groups of subjects. RESULTS A significant correlation between neutral density filter strength and intereye differences was seen for all measurement parameters in volunteers with simulated APDs. Depending on the measurement parameter and stimulus intensity, simulated APDs of 0.6 log units or more could be distinguished from normal responses. Clinically graded true APDs had intereye differences similar to simulated APDs of the same density. Those with real and simulated APDs of 0.9 log units or more could be distinguished from healthy volunteers with 80% sensitivity and 92% specificity. Responses from those with real and simulated small APDs of 0.3 to 0.6 log units could not be distinguished reliably. CONCLUSIONS Portable, personal-computer driven, electronic, infrared pupillography can record the swinging flashlight test accurately and identify large afferent pupillary defects. An affordable, portable, reliable device for identifying relative APDs would be useful in the identification and follow-up of patients with neurogenic vision loss.
منابع مشابه
Computerized binocular pupillography of the swinging flashlight test detects afferent pupillary defects.
PURPOSE To investigate the ability of a portable pupillometer, capable of 20-second binocular recordings of the swinging flashlight test (SFT), to detect relative afferent pupillary defects (rAPDs). METHODS Pupillary response curves were recorded from both eyes in healthy volunteers (n = 22) with and without simulated rAPDs (using neutral density filters (NDFs)) and in abnormal patients (n = ...
متن کاملThe usefulness of a new method of testing for a relative afferent pupillary defect in patients with ocular hypertension and glaucoma.
PURPOSE To evaluate the validity of different methods of relative afferent pupillary defect (RAPD) detection and assess the usefulness of detecting an RAPD in glaucoma patients. METHODS For this prospective observational study, we enrolled 70 of 153 consecutive glaucoma patients coming for examination. Exclusion criteria were cloudy corneas, recent surgery, fixed pupils, and other diseases pr...
متن کاملPupillography of automated swinging flashlight test in amblyopia
Relative afferent pupillary defects (RAPDs) in amblyopia have been reported, and it is widely accepted that amblyopes can have an RAPD. We investigated whether or not this could be confirmed by the use of binocular pupillography. We examined twelve patients (6 males and 6 females, aged 7-57 years) with unilateral amblyopia associated with anisometropia and/or strabismus, using binocular infrare...
متن کاملAssessment of unilateral afferent pupillary defects by pupillography.
A pupillographic technique, an adaptation of the swinging light test, is described for the measurement of unilateral afferent pupillary defects. In normal persons it yielded accurate, reproducible estimates of the magnitude of artificial afferent defects made with neutral filters of 1 to 4 log units density. In 15 studies on 8 patients with unilateral optic neuritis and 2 with unilateral compre...
متن کاملPupillary responses in amblyopia.
Relative afferent pupillary defects (RAPD) were detected in 32.3% of patients with amblyopia by a modification of the swinging flashlight test and the synoptophore. After consideration of various clinical investigations the significant factors identified in patients showing a RAPD were: anisometropia, early age of onset where strabismus was present, level of visual acuity following treatment, l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmology
دوره 107 10 شماره
صفحات -
تاریخ انتشار 2000