Accuracy and precision in photonic Doppler velocimetry.

نویسنده

  • D H Dolan
چکیده

While photonic Doppler velocimetry (PDV) is becoming a common diagnostic in dynamic compression research, its limiting accuracy and precision are not well understood. Velocity resolution is known to be inversely proportional to the time resolution, but resolution estimates differ by one to two orders of magnitude. Furthermore, resolution varies with the number of recorded signals and how these signals are analyzed. Numerical simulations reveal factors that affect accuracy and precision in PDV, and the results may be extended to a broad class of measurements. After systematic effects are eliminated, the limiting velocity uncertainty in a PDV measurement is governed by the sampling rate, the signal noise fraction, and the analysis time duration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Are Uterine and Ovarian Artery Doppler Velocimetry Values Good Pregnancy Predictors in Clomiphene Citrate Cycles?

Background We conducted this prospective study to evaluate the prognostic significance of uterine and ovarian artery Doppler velocimetry in clomiphene citrate (CC) cycles. MaterialsAndMethods A total of 80 patients with unexplained infertility were given 100 mg/day of CC from day 3 to day 7 of their cycles in this current prospective study. On cycle day 3, before administration of CC, each pati...

متن کامل

The Relationship of Uterine Artery Doppler Velocimetry Findings and Hemoglobin Concentration with Pregnancy Outcomes in Pre-eclampsia

Abstract Background: Epidemiologic studies have shown the relationship of maternal hemoglobin level and abnormal findings in uterine Doppler sonography with pregnancy- related complications. In this study, we evaluated the relationship of uterine artery Doppler velocimetry findings and hemoglobin level with the outcomes of pregnancy in women with preeclampsi...

متن کامل

Effect of window reflections on photonic Doppler velocimetry measurements.

Photonic Doppler velocimetry (PDV) has rapidly become a standard diagnostic for measuring velocities in dynamic compression research. While free surface velocity measurements are fairly straightforward, complications occur when PDV is used to measure a dynamically loaded sample through a window. Fresnel reflections can severely affect the velocity and time resolution of PDV measurements, especi...

متن کامل

I-46: Obstetrical Doppler

Accurate assessment of gestational age, fetal growth, and the detection of fetal and placental abnormalities are major benefits of sonography. Color Doppler can be used to assist in the identification of vascular architecture, detection of vascular pathology and visualization of blood flow changes associated with physiologic processes and disease states. The clinical applications of obstetrical...

متن کامل

بررسی مقاومت عروقی در داپلر شریان رحمی در زنان حامله مبتلا به فشار خون مزمن

Background and Aim: Uterine placental bloodstream pressure can be measured by Doppler ultrasonography, which is a non-invasive technique. Uterine arteries velocimetry progressively decreases during the first and second trimesters in normal gestation due to trophoblastic invasion of musculoelastic membrane of uterine spiral arteries. The relationship between trophoblastic invasion and placental ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 81 5  شماره 

صفحات  -

تاریخ انتشار 2010