Efficient Low-Lift Cooling with Radiant Distribution, Thermal Storage, and Variable-Speed Chiller Controls— Part I: Component and Subsystem Models
نویسندگان
چکیده
Component and subsystem models used to evaluate the performance of a low-lift cooling system are described. An air-cooled chiller, a hydronic radiant distribution system, variable-speed control, and peak-shifting controls are modeled. A variable-speed compressor that operates over 20:1 speed range and pressure ratios ranging from one to six is at the heart of the chiller. Condenser fan and chilled-water pump motors have independent speed controls. The load-side distribution is modeled from the refrigerant side of the evaporator to the conditioned zone as a single subsystem controlled by chilled-water flow rate for a specified instantaneous cooling load. Performance of the same chiller when operating with an all-air distribution system is also modeled. The compressor, condenser fan, and chilled-water pump motor speeds that achieve maximum coefficient of performance (COP) at a given condition are solved at each point on a grid of load and outdoor temperature. A variable-speed dehumidification subsystem is modeled and simulated as part of a dedicated outdoor air system to condition the ventilation air. A companion paper evaluates the annual cooling system energy use and potential energy savings to be gained by integrating radiant cooling, cool storage, and variable-speed compressor and transport motor controls.
منابع مشابه
Prediction of Temperature distribution in Straight Fin with variable Thermal Conductivity and Internal Heat Generation using Legendre Wavelet Collocation Method
Due to increasing applications of extended surfaces as passive methods of cooling, study of thermal behaviors and development of mathematical solutions to nonlinear thermal models of extended surfaces have been the subjects of research in cooling technology over the years. In the thermal analysis of fin, various methods have been applied to solve the nonlinear thermal models. This paper focuses...
متن کاملVertically Integrated Systems in Stand - Alone
This involves having production units distribute to the consuming units through a single vertical and central distribution network. Each fl oor is served by an indirect connected substation (Figure 3). Enhancing comfort1 and reducing energy demand2 is possible when fl oorto-fl oor (rather than building-to-building) consumption is moderate (cooling) or low (heating) temperature radiant-based sur...
متن کاملDesign of a Radiant Panel Cooling System for Summer Air Conditioning System
The main objective of this investigation was to design and investigate a radiant panel cooling system on small scale building type (office) under the central Sudan climatic conditions so as to explore the benefits of radiant cooling systems over conventional air conditioning systems (Variable air volume systems). Transient heat conduction of building (finite difference method) was used to evalu...
متن کاملModel-Based Approach for Optimizing a Data Center Centralized Cooling System
A steady-state model for a centralized cooling system is developed to enable proper provisioning of cooling resources in capital intensive projects such as data centers. The model resolves the energy equations for a cooling tower and a centralized water-cooled chiller simultaneously. It requires inputs that are readily available to the design engineer. The user inputs are the ambient conditions...
متن کاملModern Topology& Thermal Analysis of Drive for Variable Speed Pumped Storage Power Plant
Given the significant power generation and consumption of variable-speed pumped storage power plants (VSPSPs), it is crucial to enhance drive methods and decrease drive losses, thereby increasing productivity. This paper proposes the topology for VSPSP drivers with two level voltage source converters (2LVSC) with 6+1 converters. Hydraulic and electrical VSPSP models are presented, following whi...
متن کامل