Use of the pill electrode for transesophageal atrial pacing.

نویسندگان

  • J M Jenkins
  • M Dick
  • S Collins
  • W O'Neill
  • R M Campbell
  • D J Wilber
چکیده

The pill electrode, which was developed for esophageal electrocardiography, has found application in transesophageal atrial pacing during procedures such as conversion of tachycardia, electrophysiologic measurement, and acceleration of heart rate to produce stress during cardiac imaging studies. This paper presents theoretical studies that examine the relationship of interelectrode distance, current level, and pulse duration to the achievement of successful capture. Theoretical results agree with our clinical findings, i.e., current levels of 25 mA are effective to sustain capture; increased pulse duration reduces current requirements; and close bipolar spacing combines efficacy with safety. Results of animal studies performed to assess the extent of esophageal burn injury reveal that current levels in excess of 75 mA are required to produce lesions in short-term (under 30 minutes) pacing, and greater than 60 mA in long-term (4 hours) pacing. These results are based on experiments using a pulse duration of 2 ms, and the current levels that produce injury will be considerably lower if longer pulse durations are used. Typical current levels and pulse durations for successful capture are presented for 46 subjects in several new clinical applications. Termination of tachycardia, basic electrophysiologic measurements, and controlled acceleration of heart rate can be performed noninvasively with this technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transesophageal pacing : a versatile diagnostic and therapeutic tool

Transesophageal pacing and recording is done using specialized or non specialized catheters. There are two different lead types: 1) the pill electrode, connected to a flexible wire, that the patient swallows with water. This pill electrode necessitates patient collaboration. 2) a flexible catheter that can even be used in comatose or intubated patients. The pacing lead, in our cases a bipolar f...

متن کامل

Device and methods for performing transesophageal stimulation at reduced pacing current threshold

In order to reduce pacing current threshold in transesophageal stimulation, a novel multichannel transesophageal pacemaker and multichannel esophageal lead has been developed. Three different approaches to reduce pacing current threshold were clinically studied. Precise positioning of the pacing dipole allowed reduction of pacing current threshold on average by 20% over the standard bipolar tra...

متن کامل

Catheterization and Cardiovascular Diagnosis 10507-513 (1984) Thresholds for Transesophageal Atrial Pacing

To determine the thresholds for transesophageal atrial capture, as well as factors that may influence the thresholds, we measured the minimal current and pulse width required to pace the atria through transesophageal bipolar lead systems in 12 patients, ranging in age from l day to 19 years, during 19 episodes of reentrant supraventricular tachycardia. Depending on the patients’ age and size se...

متن کامل

Evaluation of transesophageal atrial pacing in the prone and lateral positions.

OBJECTIVE To develop recommendations for positioning the second-generation pacing esophageal stethoscope for transesophageal atrial pacing in patients positioned prone (P), right lateral decubitus (RLD), and left lateral decubitus (LLD). DESIGN Prospective; patients assigned consecutively. SETTING Tertiary and university hospitals. PARTICIPANTS Thirty (10 in each position group) adult pat...

متن کامل

A comparison of transoesophageal atrial pacing and direct current cardioversion for the termination of atrial flutter: a prospective, randomised clinical trial.

OBJECTIVE To compare the safety and efficacy of transoesophageal atrial pacing (TAP) with an easily swallowed pill electrode and direct current cardioversion (DCC) in patients with atrial flutter that was refractory to appropriate medical treatment. DESIGN Prospective, randomised clinical trial. SETTING Community based United States naval hospital. SUBJECTS Twenty one consecutive patients...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 8 4  شماره 

صفحات  -

تاریخ انتشار 1985