Ozone decontamination of bioclean rooms.

نویسندگان

  • T Masaoka
  • Y Kubota
  • S Namiuchi
  • T Takubo
  • T Ueda
  • H Shibata
  • H Nakamura
  • J Yoshitake
  • T Yamayoshi
  • H Doi
  • T Kamiki
چکیده

To establish a convenient method for decontaminating bioclean rooms, the effect of ozone at 80 mg/m3 for 72 h was compared with formaldehyde vaporization at an initial concentration of 150 mg/m3 with a gradual decrease to 20 mg/m3 during 72 h. Ozone was found to be inferior to formaldehyde in activity. When the bioclean room was decontaminated twice with ozone, the mean colony count per 10 cm2 was decreased to about the same level as when formaldehyde was used. Ozone had a strong caustic effect upon rubber materials. Despite these disadvantages, ozone decontamination was demonstrated to be superior to formaldehyde vaporization because of convenience, insignificant inhalation of the disinfectant by the hospital staff, and very rapid expulsion of the gas after ventilation. Because the disadvantages of ozone can be easily controlled, this study suggests that ozone decontamination is a promising method for maintaining bioclean rooms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Terminal decontamination of patient rooms using an automated mobile UV light unit.

OBJECTIVE To determine the ability of a mobile UV light unit to reduce bacterial contamination of environmental surfaces in patient rooms. METHODS An automated mobile UV light unit that emits UV-C light was placed in 25 patient rooms after patient discharge and operated using a 1- or 2-stage procedure. Aerobic colony counts were calculated for each of 5 standardized high-touch surfaces in the...

متن کامل

J. Gen. Appl. Microbiol., 48, 193–199 (2002)

For many years, the role of ozone (O3) against pathogens has been studied and it has been revealed that ozone can display biological effects and therapeutic index (Berson et al., 1996; Bocci, 1996; Hernandez et al., 1995; Turcic et al., 1995; Verrazzo et al., 1995; Wolfe et al., 1989). Ozone is a natural gas that is distributed at approximately 0.01–0.04 ppm (part per million) of the world’s at...

متن کامل

Using starch powder for the decontamination of I-131 in isolation rooms

Introduction: Various iodine isotopes are undergoing radioactive decay except Iodine-127 (I-127. Iodine I-131 is unsealed radioactive material used in nuclear medicine for both diagnostic and therapeutic procedures in Royal Hospital since 2006. In radiotoxic classification, I-131 is in group 2 element. I-131 is highly reactive element due to its volatilization nature. Currently...

متن کامل

The Impact of Ozone Treatment in Dynamic Bed Parameters on Changes in Biologically Active Substances of Juniper Berries

The development of the parameters of ozone decontamination method assuring the least possible losses of biologically active substances (essential oils and polyphenols) and their activity in common juniper (Juniperus communis (L.)) berries was studied. Ozone treatment in dynamic bed was conducted 9 times. The process was conducted under different ozone concentrations (100.0; 130.0; 160.0 g O3/m3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 43 3  شماره 

صفحات  -

تاریخ انتشار 1982