Evaluation of the Binax and Biotest urinary antigen kits for detection of Legionnaires' disease due to multiple serogroups and species of Legionella.

نویسندگان

  • R F Benson
  • P W Tang
  • B S Fields
چکیده

The Binax and the Biotest urinary antigen kits for the detection of Legionnaires' disease caused by organisms other than Legionella pneumophila were compared by testing 45 urine samples from non-Legionella pneumophila serogroup 1 patients previously positive in a broad-spectrum enzyme-linked immunosorbent assay (ELISA). Eighteen were positive with the Binax kit, and 13 were positive with the Biotest. Although neither kit is as sensitive as ELISA, these results extend the number of serogroups and species of Legionella that can be diagnosed with the Binax or Biotest kit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of legionella species in clinical samples: Comparison of polymerase chain reaction and urinary antigen detection kits.

BACKGROUND Recently, two excellent methods have been used for the diagnosis of Legionnaires' disease: urinary antigen detection and PCR. The purpose of the present study is to analyze and evaluate the sensitivity and specificity of three different urinary antigen detection kits as well as PCR. MATERIALS AND METHODS A total of 148 samples were collected from 33 patients between 1993 and 2004. ...

متن کامل

Comparison of diagnostic sensitivities of three assays (Bartels enzyme immunoassay [EIA], Biotest EIA, and Binax NOW immunochromatographic test) for detection of Legionella pneumophila serogroup 1 antigen in urine.

The Bartels enzyme immunoassay (EIA), Biotest EIA, and Binax NOW immunochromatographic test (ICT) urinary antigen kits for the detection of Legionella pneumophila serogroup 1 were compared using 178 frozen urine samples. When nonconcentrated urine samples were used, the sensitivity levels of both enzyme EIAs were significantly higher than the sensitivity level of the ICT (Bartels EIA, 71.3%; Bi...

متن کامل

Binax and biotest Legionella urinary antigen kits.

The article of Robert F. Benson et al. entitled “Evaluation of the Binax and Biotest urinary antigen kits for detection of Legionnaires’ disease due to multiple serogroups and species of Legionella” (1) states the following in the abstract: “Eighteen were positive with the Binax kit, and 13 were positive with the Biotest.” This statement is misleading since data in both the article and Table 1 ...

متن کامل

Laboratory Diagnosis of Pneumonia by Detection of Urinary Antigen Test of Legionella Pnuemophilia

Background and Aims: Legionnaires’ disease is seen in sporadic and epidemic form. The most prevalent cause is Legionella pnuemophilia (L.pneumophila), which produces a severe disease in vulnerable individuals with a high fatality rate. This study was conducted due to the wide and universal distribution of the Legionnaires’ disease, lack of conventional and accessible diagnostic meth...

متن کامل

Clinical utility of urinary antigen detection for diagnosis of community-acquired, travel-associated, and nosocomial legionnaires' disease.

The clinical utility of Legionella urinary antigen assays for the diagnosis of Legionnaires' disease was assessed by using samples from 317 culture-proven cases. The sensitivities of the Binax enzyme immunoassay (EIA) and Biotest EIA were found to be 93.7 and 94.4% for travel-associated infection and 86.5 and 76.0% for community-acquired infection but only 44.2 and 45.7% for nosocomially acquir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 38 7  شماره 

صفحات  -

تاریخ انتشار 2000