Evaluation of prescriptive fitting.
نویسنده
چکیده
The purpose of this study was to determine the minimum tolerance needed when choosing a manufacturer who custom-built analog circuitry for all-in-the-ear hearing aids to match a popular prescriptive amplification formula. Given the tolerance, a second purpose was to evaluate fitting success by calculating the differences in prescribed versus preferred gain and pre- versus postfitting perceived benefits. Eight elderly adults with mild to moderate sensorineural hearing losses participated. Real ear measurements were obtained via a probe-tube microphone system. Even when providing for the optimal scenario of custom-building the circuitry, the inherent limitations of analog technology allowed no better than a +/- 12 dB electroacoustic match to prescribed gain. Although the minimum tolerance found was less than previous studies, it was still considered excessive given the differences in prescribed gain among formulae. Regardless of the large tolerance and a preference for less gain than prescribed, the subjects reported substantial benefit with the fitting approach.
منابع مشابه
Prescriptive Procedures
Since its inception, Audiology has been concerned with hearing aid selection and the interaction of the hearing impaired person and amplification . The classic work of Watson and Knudsen (1) and Lybarger (2) suggests a long clinical interest in prescribing parameters for hearing aids according to audiometric measurements . In the early days, prescriptive procedures were neglected due to technol...
متن کاملFitting hearing aids to adults using prescriptive methods: an evidence-based review of effectiveness.
The use of a prescriptive fitting approach for hearing aid selection has been a common practice for the past 60-70 years. While there are prescriptive approaches that have been validated, in recent years it has become popular to deviate from these validated methods and use manufacturers' proprietary algorithms, which in many cases are significantly different. This research review was designed t...
متن کاملEvaluation of a protocol for fitting a wearable master hearing aid.
An experimental protocol for the prescriptive fitting of a wearable master hearing aid was evaluated. The protocol consisted of four stages: (i) acquisition of baseline audiometric data, (ii) fixed test battery using speech-in-noise as the test material, (iii) adaptive adjustments, and (iv) evaluative comparative data. The results showed that systematic improvements in hearing-aid performance w...
متن کاملDevelopment of an ear-level digital hearing aid and computer-assisted fitting procedure: an interim report.
Recent progress on the development of an ear-level digital hearing aid is described. The work includes development of a body-wearable digital hearing aid and a computer-based hearing evaluation system that exploits the flexibility afforded by digital signal processing. The prescriptive criteria and fitting procedure used with the digital hearing aid are described briefly. Design considerations ...
متن کاملEvaluation of an in-situ output probe-microphone method for hearing aid fitting verification.
Several hearing aid prescription procedures specify frequency gain functions in terms of the desired levels of amplified speech. The most direct method for verifying hearing aid fittings based on these procedures requires a measurement of amplified speech in the ear canal. This paper describes the evaluation of a probe microphone measurement procedure designed to measure amplified speech to ver...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Academy of Audiology
دوره 3 5 شماره
صفحات -
تاریخ انتشار 1992