Effect of Corneal Hydration on the Quality of the Femtosecond Laser Anterior Lamellar Cut

نویسندگان

  • Ossama Nada
  • Anca Marian
  • Nicolas Tran-Khanh
  • Michael Buschmann
  • Michel Podtetenev
  • François Vidal
  • Santiago Costantino
  • Isabelle Brunette
چکیده

The goal of this study was to assess the effect of corneal hydration on the quality of the femtosecond laser (FSL) anterior lamellar cut. The Visumax FSL was used to dissect an 8-mm-diameter corneal flap in 22 eye bank corneas showing various levels of hydration. The intended ablation depth was 220 µm in all eyes, which corresponded to the maximal depth available with this laser. After the cut, the achieved ablation depth was measured using optical coherence tomography images, flap separability was assessed by measuring the mean force generated to detach the flap, and stromal bed roughness was assessed by measuring the Haralick contrast level on the 1000× scanning electron microscopy images of the ablated surfaces. The preoperative central corneal thickness ranged from 547 to 1104 µm (mean ± SEM: 833 ± 30 µm). A negative correlation was found between the level of corneal hydration and the ablation depth measured in the mid-peripheral cornea (r =  -0.626, p = 0.003), the ablation being more superficial in more edematous corneas. The Haralick contrast also tended to increase as a function of corneal hydration (r = 0.416, p = 0.061), suggesting that laser ablation in edematous corneas results in rougher stromal surfaces. These results support the hypothesis that the quality of the FSL lamellar cut decreases as the level of corneal hydration increases. Although FSL is still considered in the field as the tool of the future for corneal dissection, a better understanding of the limits of this tool will be needed before it can replace manual or automated stromal dissection techniques in hydrated corneas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of 60 kHz and 150 kHz Femtosecond Lasers on Corneal Stromal Bed Surfaces: A Comparative Study

Purpose. To compare the effect of 60 kHz and 150 kHz femtosecond (FS) laser on the corneal stromal bed surfaces (SBS). Methods. Sixteen human donor corneal tissues unsuitable for transplantation were used. Anterior and posterior lamella was obtained using 60 kHz and 150 kHz FS laser. A standard depth of 400  μ m was set for anterior lamellar keratoplasty (ALK) and endothelial lamellar keratopla...

متن کامل

Analysis of low-energy and high-frequency femtosecond laser for the construction of deep anterior donor corneal lamellae Laser de femtossegundo de baixa energia e alta frequência na confecção de lamelas corneanas doadoras

Purpose: To evaluate the efficacy and reliability of a low-energy femtosecond laser with a high repetition rate for construction of deep anterior donor corneal lamellae. Methods: This was a prospective laboratory investigation. Twenty-five human corneal buttons were femtosecond laser cut to create thick anterior lamellae (diameter, 10mm; thickness, 500μm). The laser cuts were made using an LDV ...

متن کامل

Femtosecond Laser Assisted Deep Anterior Lamellar Keratoplasty Outcomes and Healing Patterns Compared to Manual Technique

The purpose of the study is to report the visual, refractive, and wound healing pattern outcomes of femtosecond assisted deep anterior lamellar keratoplasty (DALK) compared to the conventional manual technique. DALK was performed on 50 eyes of 47 advanced keratoconus patients. The patients were divided into two groups, 25 eyes each, depending on whether femtosecond assisted or manual DALK techn...

متن کامل

Modified femtosecond laser-assisted sutureless anterior lamellar keratoplasty.

A variation of the femtosecond laser-assisted sutureless anterior lamellar keratoplasty technique using a femtosecond laser incision for surgical management of anterior corneal disease is described. Six patients with corneal scars were treated with the laser to create a horizontal lamellar bed interface in the cornea of the donor and recipient eyes, with a manual partial-thickness vertical trep...

متن کامل

Femtosecond Laser and Big-Bubble Deep Anterior Lamellar Keratoplasty: A New Chance

Purpose. To report the 12-month follow-up after big-bubble deep anterior lamellar keratoplasty (DALK) assisted by femtosecond laser that we have called IntraBubble. Methods. A 60 kHz IntraLase femtosecond laser (Abbott Medical Optics) firstly created a 30° angled intrastromal channel to insert the air injection cannula, 50 μ above the thinnest corneal site measured by Sirius Scheimpflug camera ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014