Elemental distributions and microtensile bond strength of the adhesive interface to normal and caries-affected dentin.
نویسندگان
چکیده
The aim of this study was to evaluate the microtensile bond strength (microTBS) and the elemental contents of the adhesive interface created to normal versus caries-affected dentin. Extracted human molars with coronal carious lesions were used in this study. A self-etching primer/adhesive system (Clearfil Protect Bond) was applied to flat dentin surfaces with normal and caries-affected dentin according to the manufacturer's instructions. After 24 h water storage, the bonded specimens were cross-sectioned and subjected to a microTBS test and electron probe microanalysis for the elemental distributions [calcium (Ca), phosphorus (P), magnesium (Mg), and nitrogen (N)] of the resin-dentin interface after gold sputter-coating. The microTBS to caries-affected dentin was lower than that of normal dentin. The demineralized zone of the caries-affected dentin-resin interface was thicker than that of normal dentin (approximately 3 microm thick in normal dentin; 8 microm thick in caries-affected dentin), and Ca and P in both types of dentin gradually increased from the interface to the underlying dentin. The caries-affected dentin had lost most of its Mg content. The distributions of the minerals, Ca, P, and Mg, at the adhesive interface to caries-affected dentin were different from normal dentin. Moreover, a N peak, which was considered to be the collagen-rich zone resulting from incomplete resin infiltration of exposed collagen, was observed to be thicker within the demineralized zone of caries-affected dentin compared with normal dentin.
منابع مشابه
Microtensile bond strength of clearfil SE bond to caries-affected dentin and normal dentin
Microtensile bond strength of clearfil SE bond to caries-affected dentin and normal dentin Dr. A. Ghasemi* - Dr. M. Bargrizan** - Dr. M. Mahmoodi*** *- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Pedodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. ***...
متن کاملShear bond strength of different adhesive systems to normal and caries-affected dentin
BACKGROUND AND AIM: According to the effect of the adhesive and substrate type on the bond strength, examination of the adhesive is required in all aspects. The aim of this study was to evaluate the shear bond strength of different adhesive systems to normal dentin (ND) and caries affected dentin (CAD) in permanent teeth. METHODS: Thirty extracted molars with small occlusal caries were selected...
متن کاملSodium fluoride addition to a two-step etch-and-rinse adhesive system: effect on dentin microtensile bond strength and durability
Introduction: Studies have suggested that sodium fluoride (NaF) has an inhibitory effect on the activity of endogenous matrix metalloproteinase enzymes. This study assessed the effect of a fluoride-containing adhesive on microtensile bond strength (µTBS) over time. Material & Methods: In this experimental study, 36 extracted third molars were used to evaluate the µTBS of...
متن کاملBonding of self-etch and total-etch adhesives to carious dentin.
Carious dentin is partially demineralized and contains mineral crystals in the tubules. This may permit the deeper etching of intertubular dentin but prevent resin tag formation during bonding. We hypothesize that resin adhesives will produce lower bond strengths to caries-infected and caries-affected dentin compared with normal dentin. We tested this by measuring the microtensile bond strength...
متن کاملEvaluation of antibacterial and fluoride-releasing adhesive system on dentin--microtensile bond strength and acid-base challenge.
This study evaluated the influence of a fluoride-containing adhesive on microtensile bond strength (microTBS) to dentin, as well as analyzed the dentin-adhesive interface after acid-base challenge. Experimental groups were: G1--Clearfil SE Bond control (SE); G2--Clearfil Protect Bond control (PB); G3--Primer[SE]/Adhesive[PB]; G4--Primer[PB]/Adhesive[SE]. For microTBS evaluation, dentin surfaces...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical materials research. Part B, Applied biomaterials
دوره 72 2 شماره
صفحات -
تاریخ انتشار 2005