Direct computation of multiple 3D flow convergence isovelocity surfaces from digital 3D reconstruction of colour Doppler data of the flow convergence region: an in vitro study with differently shaped orifices.
نویسندگان
چکیده
AIMS Evaluation of the accuracy of direct computation of multiple three-dimensional (3D) flow convergence (FC) isovelocities by using digital reconstruction of colour Doppler data of the flow convergence region. METHODS AND RESULTS We used a conventional ultrasound system (ATL HDI 3000) connected to a computer workstation via Ethernet link. The digital 3D datasets were directly transferred to a Silicon Graphic Imaging Octane workstation for later measurement. We generated nine pulsatile flows (20-60 ml/beat), with peak flow rates (67-180 ml/s), through three orifices (circular, rectangular and triangular, S=0.24 cm(2)). The 3D reconstructions of FC surface areas from multi-threshold velocities, including aliasing velocities were analysed to quantify the peak flow rate. For all orifices, linear regression demonstrated excellent correlation between the 3D calculated and electromagnetic flow meter recorded data. While there was a high correlation for 3D computation of flow rate from the single best Nyquist of 24 cm/s (r=0.97-0.98, SEE=7 .75-12.58 ml/s), the ability to average three threshold velocities (15, 18 and 24 cm/s) yielded an improved correlation (r=0.98-0.99, SEE=5.70-7.73 ml/s). CONCLUSIONS Direct computation of multiple 3D FC isovelocities from digital reconstruction of colour Doppler data of the FC region provides the potential to accurately quantify the complex asymmetric spatial flow events at any selected velocity.
منابع مشابه
Three-dimensional reconstruction of color Doppler-imaged flow convergence region: limitations.
Doppler–Imaged Flow Convergence Region: Limitations To the Editor: I would like to congratulate Ishii et al1 for a very interesting study in the February 6, 2001, issue of Circulation on the use of 3D reconstruction of the color Doppler–imaged flow convergence region in ventricular septal defects. Their study, however, fails to mention 2 significant limitations of the flow convergence method. F...
متن کاملQuantitative assessment of severity of ventricular septal defect by three-dimensional reconstruction of color Doppler-imaged vena contracta and flow convergence region.
BACKGROUND The aim of the present study was to investigate the feasibility and potential value of the computer-controlled, 3D, echocardiographic reconstruction of the color Doppler-imaged vena contracta (CDVC) and the flow convergence (FC) region as a means of accurately and quantitatively estimating the severity of a ventricular septal defect (VSD). METHODS AND RESULTS We performed a 3D reco...
متن کاملO-28: Anti-Mullerian Hormone and 3D-Power Doppler Histogram: Markers of Ovarian Function with In vitro Fertilization Treatment
Background: The aim of this study was to investigate the ability of three-dimensional (3D) ultrasonography and anti-Mullerian hormone (AMH) to predict successful embryo development in patients undergoing in vitro fertilization (IVF) treatment. Materials and Methods: We prospectively studied 28 patients undergoing IVF treatment, using 3D ultrasound Sono automatic volume calculation (AVC) and a 3...
متن کاملDetermination of the most appropriate velocity threshold for applying hemispheric flow convergence equations to calculate flow rate: selected according to the transorifice pressure gradient. Digital computer analysis of the Doppler color flow convergence region.
BACKGROUND While flow convergence methods have been promising for calculating volume flows from color Doppler images, it appears that the velocity threshold used and the transorifice pressure gradient dramatically influence the accuracy of application of the simple hemispheric flow convergence equation for calculation of flow rate. The present in vitro study was performed to determine whether t...
متن کاملFlow Convergence Region
Background. While flow convergence methods have been promising for calculating volume flows from color Doppler images, it appears that the velocity threshold used and the transorifice pressure gradient dramatically influence the accuracy of application of the simple hemispheric flow convergence equation for calculation of flow rate. The present in vitro study was performed to determine whether ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology
دوره 1 4 شماره
صفحات -
تاریخ انتشار 2000