Uncemented application of cemented LCS knee prosthesis leading to knee pain.

نویسندگان

  • William J Gaine
  • Aslam Mohammed
چکیده

(DePuy Orthopaedics Inc, Warsaw, Ind) prosthesis is a total condylar, low contact stress, mobile bearing prosthesis, which allows retention or excision of the posterior cruciate ligament. The cemented version has a sandblasted finish on cobalt-chromemolybdenum metallic surface for cement fixation, whereas the cementless version uses Porocoat sintered beads (DePuy) for bone ingrowth (Figure 1). This article highlights a previously unreported cause of knee pain after arthroplasty, and emphasizes the importance of a surgeon’s familiarity with implant components. This is particularly relevant to the low-volume arthroplasty surgeon who is more susceptible to complications.1

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cemented versus Uncemented Oxford Unicompartmental Knee Arthroplasty: Is There a Difference?

Purpose. The use of uncemented unicompartmental knee prostheses has recently increased. However, few studies on the outcomes of uncemented unicompartmental knee prostheses have been performed. The purpose of this study was to compare the outcomes of cemented and uncemented Oxford unicompartmental knee arthroplasty. Materials and Methods. This retrospective observational study evaluated the clin...

متن کامل

Tibial Component in Revision of Total Knee Arthroplasty: Comparison between Cemented and Hybrid Fixation

OBJECTIVE To compare the clinical, radiographic and medium-term follow-up results from two fixation methods for the tibial component in revision procedures on total knee prostheses: cemented (tray and stem) and hybrid (cemented tray and uncemented, nonporous canal-filling stem). METHODS Between August 1999 and November 2005, 30 revision procedures on total knee arthroplasties were performed o...

متن کامل

Fatigue fracture of the femoral component in a mobile bearing knee prosthesis.

Stress fracture of the femoral component is a rare complication following total knee arthroplasty. We report one such complication which occurred 6.5 years after primary implantation of an uncemented meniscal Low Contact Stress (LCS) prosthesis. The fracture affected the medial condyle of the femoral component, and a large osteolytic lesion was present in the underlying femoral condyle. The pat...

متن کامل

Survival and clinical function of cemented and uncemented prostheses in total knee replacement: a meta-analysis.

Using meta-analysis we compared the survival and clinical outcomes of cemented and uncemented techniques in primary total knee replacement. We reviewed randomised controlled trials and observational studies comparing cemented and uncemented fixation. Our primary outcome was survival of the implant free of aseptic loosening. Our secondary outcome was joint function as measured by the Knee Societ...

متن کامل

Cement versus cementless fixation in total knee arthroplasty.

A prospectively studied group of 55 uncemented Press Fit Condylar total knee arthroplasties was compared retrospectively with a matched group of 51 cemented Press Fit Condylar total knee arthroplasties at a mean of 10 years after operation. For the cemented group, the pain and function scores improved from 32 and 45 preoperatively to 95 and 77, respectively. For the uncemented group the scores ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 27 4  شماره 

صفحات  -

تاریخ انتشار 2004