Minimizing EIT image artefacts from mesh variability in finite element models.
نویسندگان
چکیده
Electrical impedance tomography (EIT) solves an inverse problem to estimate the conductivity distribution within a body from electrical simulation and measurements at the body surface, where the inverse problem is based on a solution of Laplace's equation in the body. Most commonly, a finite element model (FEM) is used, largely because of its ability to describe irregular body shapes. In this paper, we show that simulated variations in the positions of internal nodes within a FEM can result in serious image artefacts in the reconstructed images. Such variations occur when designing FEM meshes to conform to conductivity targets, but the effects may also be seen in other applications of absolute and difference EIT. We explore the hypothesis that these artefacts result from changes in the projection of the anisotropic conductivity tensor onto the FEM system matrix, which introduces anisotropic components into the simulated voltages, which cannot be reconstructed onto an isotropic image, and appear as artefacts. The magnitude of the anisotropic effect is analysed for a small regular FEM, and shown to be proportional to the relative node movement as a fraction of element size. In order to address this problem, we show that it is possible to incorporate a FEM node movement component into the formulation of the inverse problem. These results suggest that it is important to consider artefacts due to FEM mesh geometry in EIT image reconstruction.
منابع مشابه
Correcting for variability in mesh geometry in Finite Element Models
Andy Adler1, and William R.B. Lionheart2 1Systems and Computer Engineering, Carleton University, Ottawa, Canada 2School of Mathematics, University of Manchester, UK Abstract: We show that variability in the finite element model (FEM) geometry in the EIT forward model can result in image artefacts in the reconstructed images. We explain these artefacts as the result of changes in the projection ...
متن کاملEffects of Warping Finite Element Meshes for the Forward Model of the Head in Eit
The use of realistic FE head models in EIT of brain function confers significant advantages, but image quality is critically dependent on mesh geometrical integrity. Generation of accurate models for individual subjects is time-consuming, so warping an existing idealised mesh to closely approximate specific patient geometry is being investigated. The head was modelled as an ellipsoid to obtain ...
متن کاملOptical breast shape capture and finite-element mesh generation for electrical impedance tomography.
X-ray mammography is the standard for breast cancer screening. The development of alternative imaging modalities is desirable because mammograms expose patients to ionizing radiation. Electrical impedance tomography (EIT) may be used to determine tissue conductivity, a property which is an indicator of cancer presence. EIT is also a low-cost imaging solution and does not involve ionizing radiat...
متن کاملA new protocol for the rapid generation of accurate anatomically realistic Finite Element Meshes of the head from T1 MRI scans
Reconstruction of images in Electrical Impedance Tomography (EIT) of brain function in the adult head benefits from the use of accurate numerical models, which may utilize meshes created by the Finite Element Method (FEM). Previously, these have been produced by manual segmentation and parametric representation of surfaces which were later meshed, but this was time consuming and required CAD sp...
متن کاملThe impact of electrode area, contact impedance and boundary shape on EIT images.
Electrical impedance tomography (EIT) measures the conductivity distribution within an object based on the current applied and voltage measured at surface electrodes. Thus, EIT images are sensitive to electrode properties (i.e. contact impedance, electrode area and boundary shape under the electrode). While some of these electrode properties have been investigated individually, this paper inves...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiological measurement
دوره 32 7 شماره
صفحات -
تاریخ انتشار 2011