Complications of permanent dual-chamber pacing such as late purulent pacemaker pocket infection with broken and looped atrial lead, complicated by pulmonary embolism after transvenous lead removal: a case report.
نویسندگان
چکیده
We present a complication of the infected pacing system extraction by lobular pneumonia in a 73-year-old female patient. The pacing system involved DDD pacemaker, atrial and ventricular endocardial leads implanted 12 year beforehand. The defect of the atrial lead emerged during the pacemaker replacement 4 years ago. The diagnosis of the injury cause and its reparation were not undertaken at that time. An interruption of the atrial lead which resulted in the formation of a loop inside the cardiac chamber was found when purulant pacemaker pocket infection had been diagnosed. The patient was referred for the pacing system extraction after preoperative specific antibiotic treatment. After a long-lasting, difficult, two-step leads extraction procedure, pneumonia developed. An echocardiogram revealed enlargement of the right atrium and ventricle, with elevated pulmonary artery pressure up to 40 mmHg. An atypical chest X-ray with the presence of a large pleural liquid volume led to the work-up of hemorrhagic complications and postponed the antithrombotic therapy. With the delay of 1.5 month the pulmonary scintigraphy showed features of pulmonary embolism. The embolism was most likely caused by a vegetation mobilized from the endocardial lead and/or endocardium during the extraction maneuvers. Before the surgery, the vegetations attached to the leads or to the endocardium had not been visualized. Anticoagulant therapy with antivitamins K was successful, which resulted in the pulmonary pressure normalization. The patient has remained in a good condition for the next 3 months of follow-up.
منابع مشابه
The Improvement of the Atrial Flutter Rhythm upon the Removal of the Infected Permanent Pacemaker Lead
Pacemaker infection has multiple risk factors. Its presentation is most often similar to infected endocarditis and the diagnosis is made through studying blood cultures. Transesophageal echocardiography can confirm the diagnosis. The most common microorganisms are staphylococcus speciesis. As a matter of fact, complete pacemaker removal appears to be the only definite treatment. We presented a ...
متن کاملEarly complications of permanent pacemaker implantation: no difference between dual and single chamber systems.
OBJECTIVE To evaluate the incidence of intraoperative and early postoperative complications (up to two months after implant) of endocardial permanent pacemaker insertion in all patients under-going a first implant at a referral centre. METHODS Prospective evaluation of all endocardial pacemaker implantation procedures performed from April 1992 to January 1994 carried out by completion of stan...
متن کاملInadvertent malposition of a permanent pacemaker ventricular lead into the left ventricle which was initially missed and diagnosed two years later: a case report
INTRODUCTION Inadvertent malposition of a pacemaker ventricular lead into the left ventricle is an uncommon event, and its actual incidence is probably unknown. It may be underestimated and underreported because of a possible asymptomatic course. A 12-lead electrocardiogram is important to confirm proper placement. CASE PRESENTATION We report a case of a 60-year-old Caucasian man with a malpo...
متن کاملA combined atrial/ventricular lead for permanent dual-chamber cardiac pacing applications.
A new urethane insulated dual unipolar atrial/ventricular transvenous lead has been developed to facilitate implantation of permanent dual-chamber cardiac pacing systems in man. The atrial portion of the lead has tines and is designed to retain a permanent J configuration, while the coaxially situated ventricular lead is freely and independently adjustable and incorporates a ring tip electrode ...
متن کاملTrans-Fontan baffle placement of an endocardial systemic ventricular pacing lead
Introduction Patients with single-ventricle physiology palliated to a Fontan can be at risk for high-grade atrioventricular block, necessitating permanent pacemaker placement. Historically, epicardial leads have been used for these patients given the concern for clot formation within the Fontan pathway or systemic ventricle. However, epicardial pacing systems are fraught with issues, including ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Polskie Archiwum Medycyny Wewnetrznej
دوره 118 5 شماره
صفحات -
تاریخ انتشار 2008