A novel method for the remote condition assessment of buried pipelines using low-frequency axisymmetric waves

نویسنده

  • J M Muggleton
چکیده

“Mapping the Underworld” is a large multi-disciplinary, multi-university research programme taking place in the UK, which aims to revolutionize the way we undertake streetworks. Within this programme, a number of vibration-based techniques for remotely detecting and locating buried pipes have been developed. Relying either on the direct excitation of a pipe as it comes up to the surface or excitation of the ground in the vicinity of a buried pipe, mapping the ground surface vibration response allows information to be gathered concerning the pipe’s exact position. However, contained within this surface response is often information which could, if utilized appropriately, provide insights into the condition of the pipe as well as its location. Furthermore, critical information regarding the condition of the ground in which a pipe is buried could, in some circumstances, be gleaned. In this paper, how this additional information might be extracted, used and eventually exploited is explored. Providing the basis for work currently being undertaken in a new programme, “Assessing the Underworld”, example results are presented which demonstrate the immense potential of the proposed methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Remote pipeline assessment and condition monitoring using low-frequency axisymmetric waves: a theoretical study of torsional wave motion

Waves that propagate at low frequencies in buried pipes are of considerable interest in a variety of practical scenarios, for example leak detection, remote pipe detection, and pipeline condition assessment and monitoring. Particularly useful are the n=0, or axisymmetric, modes in which there is no displacement (or pressure) variation over the pipe cross section. Previous work has focused on tw...

متن کامل

ANOVELMONITORINGTECHNIQUE TO DEFINE CP CRITERIA FOR BURIED PIPELINES UNDER AC CORROSION CONDITION

Abstract: The risks of alternating current (AC) corrosion and overprotection increasingly demand new criteria forcathodically protected pipelines. To assess the risk of AC corrosion, new cathodic protection (CP) criteria have beenproposed based on DC/AC current densities measurements using coupons. The monitoring system designed for thisproject was based on the instant-off method, with steel co...

متن کامل

A SURVEY ON THE EFFECT OF SOIL COMPOSITION IN CORROSION BEHAVIOR OF CATHODICALLY PROTECTED BURIED PIPELINES UNDER AC INDUCED CONDITION

Abstract: Due to the expansion of high voltage Alternating Current (AC) power transmission lines and cathodically protected buried pipelines, it is becoming more and more difficult to construct them with enough safe distances between them. Thus, the pipelines are frequently exposed to induced AC interferences, which result in perturbation of Cathodic Protection (CP) due to AC corrosion. To s...

متن کامل

Ultrasonic guided waves reflection from simple dent in pipe for defect rate estimation and parameters determination of axisymmetric wave generation source

In this paper, the reflection of ultrasonic guided waves from simple dent in pipes has been investigated using finite element method and the relationship between reflection coefficient of these waves and deformation rate has been determined. Also, the effect of the parameters of wave generation source on the generated wave field has been investigated using normal modes expansion method. At firs...

متن کامل

Numerical and Empirical Investigation of Flow Separation Phenomenon around Semi-buried Pipelines due to Steady Currents

In this paper, in order to understand the flow-pipe interaction more clearly, the variations on flow pattern around semi-buried pipelines due to steady current have physically and numerically been investigated. In physical modeling section, the experiments have been carried out in a flume with 10 meter length, 0.3 meter width and 0.5 meter depth using a P.V.C pipe with 6.35 cm in diameter (for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016