Suitability of single tissue dielectric constant measurements to assess local tissue water in normal and lymphedematous skin.

نویسندگان

  • Harvey N Mayrovitz
  • Suzanne Davey
  • Elizabeth Shapiro
چکیده

Previous reports described the use of average tissue dielectric constant (TDC) measurements to assess local tissue water and its change. Our goal was to determine if a single TDC measurement could be used in place of the average of multiple measurements. The comparison criteria used to test this was the extent to which single and averaged measurements yielded similar TDC values in both normal and lymphedematous tissue. Measurements were made in two groups of women; a control group (n = 20) and a group with unilateral arm lymphedema (n = 10). In the control group, TDC was measured to multiple depths (0.5-5.0 mm) on both ventral forearms and to a depth of 2.5 mm on the lateral thorax on both body sides. In the lymphedematous group, TDC was measured on both ventral forearms to a depth of 2.5 mm. Results showed that the 95% confidence interval for differences between single and averaged TDC values was less than +/-1 TDC unit and that the limits of agreement between methods was less than +/-2.5 TDC units (+/-6.5%) for each condition, site and depth measured. This finding suggests that where this level of agreement is acceptable suitable clinical assessments can be made using a single TDC measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Local tissue water changes assessed by tissue dielectric constant: single measurements versus averaging of multiple measurements.

Previous reports describe the use of average tissue dielectric constant (TDC) measurements to assess local tissue water and its change. Our goal was to determine if a single TDC measurement could be used in place of the average of multiple measurements. The comparison criteria used to test this was the extent to which single and averaged measurements yielded similar TDC values in both normal an...

متن کامل

Tissue dielectric constant (TDC) measurements as a means of characterizing localized tissue water in arms of women with and without breast cancer treatment related lymphedema.

Quantitative measurements to detect lymphedema early in persons at-risk for breast cancer (BC) treatment-related lymphedema (BCRL) can aid clinical evaluations. Since BCRL may be initially manifest in skin and subcutis, the earliest changes might best be detected via local tissue water (LTW) measurements that are specifically sensitive to such changes. Tissue dielectric constant (TDC) measureme...

متن کامل

Assessing lymphedema by tissue indentation force and local tissue water.

Tissue water and mechanical property changes accompany lymphedema, however the relationship between these changes, if any, is unclear. Local tissue water is quantifiable using the tissue's dielectric constant (TDC), but a non-gravity dependent handheld clinical assessment tool to easily quantify corresponding local tissue properties is not widely available. Herein such a tool is described along...

متن کامل

Local tissue water in at-risk and contralateral forearms of women with and without breast cancer treatment-related lymphedema.

BACKGROUND Quantitative measurements to help detect incipient or latent lymphedema in patients at risk for breast cancer treatment-related lymphedema (BCRL) are potentially useful supplements to clinical assessments. Suitable measurements for routine use include arm volumes, arm bioimpedance, and local tissue water (LTW) determined from the tissue dielectric constant (TDC). Because BCRL initial...

متن کامل

Age-related differences in tissue dielectric constant values of female forearm skin measured noninvasively at 300 MHz.

BACKGROUND/PURPOSE We hypothesized that reported age-related shifts in skin water from less-to-more mobile states would result in increased skin tissue dielectric constant (TDC) values as TDC values depend strongly on water content and state. One aim was to test this hypothesis. Further, as skin-to-fat TDC values are used as a tool for edema and lymphedema assessment, a second aim was to establ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical physiology and functional imaging

دوره 29 2  شماره 

صفحات  -

تاریخ انتشار 2009