A highly pH-sensitive Zn(II) chemosensor.

نویسندگان

  • Carla Bazzicalupi
  • Andrea Bencini
  • Silvia Biagini
  • Enrico Faggi
  • Giovanna Farruggia
  • Giulia Andreani
  • Paola Gratteri
  • Luca Prodi
  • Alessio Spepi
  • Barbara Valtancoli
چکیده

Proton and Cu(II), Zn(II), Cd(II) and Pb(II) binding by ligand H(2)L, containing two bis(aminoethyl)amine (dien) units connected by a 2',7'-dichlorofluorescein (DCF) unit has been analyzed by means of potentiometric, UV-vis and fluorescence emission measurements. Considering proton binding, the ligand in its fully deprotonated form, L(2-), binds up to four acidic protons in the alkaline pH region. These protonation steps occur on the amine groups, whereas protonation of DCF takes place only below pH 4. In metal complexation, the ligand displays a marked selectivity for Zn(II) over Cd(II) and Pb(II), due to the better accommodation of the smaller and harder Zn(II) ion within the binding pocket generated by a dien unit and the adjacent deprotonated oxygen. The fluorescence emission study points out that Zn(II) binding is accompanied by a marked increase of the DCF emission from neutral to slightly alkaline pH values, where protonated forms of the complex are present in solution. The system is weakly emissive at slightly acidic pH values, where Zn(II) is essentially not bound to the receptor and above pH 9.5, probably due to the formation of the not protonated [ZnL] complex. Cd(II) binding gives rise to a much less intense increase of the emission only above pH 8.5, whereas Cu(II) and Pb(II) complexation leads to fluorescence quenching. Furthermore, the interaction of H(2)L with cells was investigated to explore its application as a new sensor for the evaluation of cellular Zn(II) content and distribution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A highly selective and sensitive fluorescent PET (photoinduced electron transfer) chemosensor for Zn(II).

The naphthalimide derivative 1 was designed as a fluorescence PET sensor for Zn(II); 1 showed excellent selectivity for Zn(II) at pH 7.4, even in the presence of other competitive cations, the emission, being pH independent above pH 3.5, was switched on upon Zn(II) recognition.

متن کامل

A Sensitive Ratiometric Fluorescent Sensor for Zinc(II) with High Selectivity

A new fluorescent Zn²⁺ chemosensor (P1) based on a functionalized porphyrin was synthesized and characterized. P1 displayed dramatic ratiometric variations in absorption and fluorescent emission spectra upon exposure to Zn²⁺ due to the formation of a 1:1 Zn²⁺/P1 complex. The sensor also exhibited high selectivity and sensitivity toward Zn²⁺ over other common metal ions in the physiological pH r...

متن کامل

A highly selective and sensitive luminescent chemosensor for Zn2+ ions based on cyclometalated platinum(II) complexes.

A novel luminescent Zn(2+) ions chemosensor, a cyclometalated platinum(II) bipyridyl acetylide complex, was designed. Of particular significance is that it shows a high sensitivity towards Zn(2+) ions without interference from other biologically important cations in acetonitrile. The tautomerization of amide favors detecting Zn(2+) ions among other HTM (heavy and transition metal) ions in aqueo...

متن کامل

Graphene Oxide-terpyridine Conjugate: A Highly Selective Colorimetric and Sensitive Fluorescence Nano-chemosensor for Fe2+ in Aqueous Media

A graphene oxide-terpyridine conjugate (GOTC) based colorimetric and fluorescent nano-chemosensor was synthesized. It showed high selectivity and sensitivity for Fe2+ and Fe3+ ions in neutral aqueous solution over other metal ions such as Li+, Na+, Ba2+, Ca2+, Al3+, Cd2+, Co2+, Cu2+, Hg2+, Mn...

متن کامل

A colorimetric "naked-eye" Cu(II) chemosensor and pH indicator in 100% aqueous solution.

A new, highly selective and sensitive colorimetric chemosensor 1 for detection of Cu(2+) ions in aqueous solution was developed. Receptor 1 detected Cu(2+) ions by changing its color from colorless to yellow. Moreover, the Cu(2+)-sensitive compound was used as a colorimetric pH detector based on a color change due to 1-Cu(2+) complex formation identifiable by the naked eye.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dalton transactions

دوره 39 30  شماره 

صفحات  -

تاریخ انتشار 2010