ROLLING CONTACT ORTHOPAEDIC JOINT DESIGN by

نویسندگان

  • Alexander Henry Slocum
  • Alexander H. Slocum
  • Kripa K. Varanasi
  • David E. Hardt
چکیده

Arthroplasty, the practice of rebuilding diseased biological joints using engineering materials, is often used to treat severe arthritis of the knee and hip. Prosthetic joints have been created in a “biomimetic” manner to reconstruct the shape of the biological joint. We are at a disadvantage, however, in that metals and polymers used to replace bone and articular cartilage often wear out too soon, leading to significant morbidity. This thesis explores the use of kinetic-mimicry, instead of bio-mimicry, to design prosthetic rolling contact joints, including knee braces, limb prosthetics, and joint prostheses, with the intent of reducing morbidity and complications associated with joint/tissue failure. A deterministic approach to joint design is taken to elucidating six functional requirements for a prosthetic tibiofemoral joint based on anatomical observations of human knee kinetics and kinematics. Current prostheses have a high slide/roll ratio, resulting in unnecessary wear. A rolling contact joint, however, has a negligible slide/roll ratio; rolling contact prostheses would therefore be more efficient. A well-established four-bar linkage knee model, in a sagittal plane that encapsulates with the knee’s flexion/extension degree of freedom, is used to link human anatomy to the shape of rolling cam surfaces. The first embodiment of the design is a flexure coupling-based joint for knee braces. Failure mode analysis, followed by cyclic failure testing, has shown that the prototype joint is extremely robust and withstood half a million cycles during the first round of tests. Lubrication in the joint is also considered: microand nano-textured porous coatings are investigated for their potential to support the formation of favorable lubrication regimes. Hydrodynamic lubrication is optimal, as two surfaces are separated by a fluid gap, thus mitigating wear. Preliminary results have shown that shear stress is reduced by more than 60% when a coating is combined with a shear thinning lubricant like synovial fluid. These coatings could be incorporated into existing joint prostheses to help mitigate wear in current technology. This thesis seeks to describe improvements to the design of prosthetic joints, both existing and future, with the intent of increasing the overall quality of care delivered to the patient. Thesis Supervisor: Kripa K. Varanasi Title: Doherty Associate Professor of Mechanical Engineering

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Static Stability Analysis of a Planar Object Grasped by Multifingers with Three Joints

This paper discusses static stability of a planar object grasped by multifingers with three joints. Each individual joint (prismatic joint or revolute joint) is modeled as a linear spring stiffness. The object mass and the link masses are also included. We consider not only pure rolling contact but also frictionless sliding contact. The grasp stability is investigated using the potential energy...

متن کامل

Safety and Efficacy of Casting During COVID-19 Pandemic: A Comparison of the Mechanical Properties of Polymers Used for 3D Printing to Conventional Materials Used for the Generation of Orthopaedic Orthoses

To reduce the risk of spread of the novel coronavirus (COVID-19), the emerging protocols are advising for less physicianpatientcontact, shortening the contact time, and keeping a safe distance. It is recommended that unnecessary castingbe avoided in the events that alternative methods can be applied such as in stable ankle fractures, and hindfoot/midfoot/forefoot injuries. Fib...

متن کامل

Kinematic and dynamic analysis of an anatomically based knee joint.

This paper presents a knee-joint model to provide a better understanding on the interaction between natural joints and artificial mechanisms for design and control of rehabilitation exoskeletons. The anatomically based knee model relaxes several commonly made assumptions that approximate a human knee as engineering pin-joint in exoskeleton design. Based on published MRI data, we formulate the k...

متن کامل

Review of the Potential Indications and Contraindications for Equine Oral Joint Health Supplements

Despite the widespread use of oral joint health supplements in the equine practice, there is limited evidence-based information describing either the appropriate or optimal use of these products. This review critically examines the current literature and identifies potential indications, contraindications, and dosing recommendations. Authors’ addresses: Rolling Thunder Scientific, 34 Lasby Lane...

متن کامل

Patellofemoral joint contact area increases with knee flexion and weight-bearing.

Patellofemoral pain is a common and debilitating disorder. Elevated cartilage stress of the patellofemoral joint is hypothesized to play a role in the onset of pain. Estimating cartilage stress requires accurate measurements of contact area. The purpose of this study was to estimate patellofemoral joint contact areas in a group of healthy, pain-free subjects during upright, weight-bearing condi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013