General Phase Regularized Reconstruction using Phase Cycling
نویسندگان
چکیده
PURPOSE To develop a general phase regularized image reconstruction method, with applications to partial Fourier imaging, water-fat imaging and flow imaging. THEORY AND METHODS The problem of enforcing phase constraints in reconstruction was studied under a regularized inverse problem framework. A general phase regularized reconstruction algorithm was proposed to enable various joint reconstruction of partial Fourier imaging, water-fat imaging and flow imaging, along with parallel imaging (PI) and compressed sensing (CS). Since phase regularized reconstruction is inherently non-convex and sensitive to phase wraps in the initial solution, a reconstruction technique, named phase cycling, was proposed to render the overall algorithm invariant to phase wraps. The proposed method was applied to retrospectively under-sampled in vivo datasets and compared with state of the art reconstruction methods. RESULTS Phase cycling reconstructions showed reduction of artifacts compared to reconstructions without phase cycling and achieved similar performances as state of the art results in partial Fourier, water-fat and divergence-free regularized flow reconstruction. Joint reconstruction of partial Fourier + water-fat imaging + PI + CS, and partial Fourier + divergence-free regularized flow imaging + PI + CS were demonstrated. CONCLUSION The proposed phase cycling reconstruction provides an alternative way to perform phase regularized reconstruction, without the need to perform phase unwrapping. It is robust to the choice of initial solutions and encourages the joint reconstruction of phase imaging applications. Magn Reson Med 80:112-125, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
منابع مشابه
Phase-regularized polygon computer-generated holograms.
The dark-line defect problem in the conventional polygon computer-generated hologram (CGH) is addressed. To resolve this problem, we clarify the physical origin of the defect and address the concept of phase-regularization. A novel synthesis algorithm for a phase-regularized polygon CGH for generating photorealistic defect-free holographic images is proposed. The optical reconstruction results ...
متن کاملEvaluation of the potential impact of reconstruction method on dyssynchrony parameters derived by phase analysis of gated-SPECT MPI: Comparison of two quantitative software
Introduction: Gated SPECT myocardial perfusion scanning has new capabilities in addition to its main applications such as left ventricular dyssynchrony using phase analysis. Phase analysis has been investigated through various software including Emory Cardiac Toolbox (ECTb) and Quantitative Gated SPECT (QGS). The aim of this study is to evaluate the effect of reconstruction par...
متن کاملاثر رکاب زدن و خستگی بر تغییرات همانقباضی عضلات اطراف زانو طی دویدن ورزشکاران سهگانه
Objective: The purpose of this study was to determine the effect of cycling fatigue on co-activation of knee muscles during running in novice triathletes. Methods: Twelve novice male triathletes aged 23.7±2.1 years participated in this quasi experimental study. Surface electromyographic activity from gastrocnemius, rectus femoris, vastus medialis, vastus lateralis, biceps femoris and se...
متن کاملPhase Only Synthesis of Antenna Patterns Using Iterative Restoration Methods
In this work, the method of iterative Fourier transform phase reconstruction, conventionally used in holography and optical image reconstruction, is applied to phase only synthesis of antenna patterns. The method is applied to two types of pattern synthesis problems: "main lobe beam shaping" and "side-lobe-level reduction". The proposed method is most useful in the efficient employment of attai...
متن کاملPhaseless Diffraction Tomography with Regularized Beam Propagation
In recent years, researchers have obtained impressive reconstructions of the refractive index (RI) of biological objects through the combined use of advanced physics (nonlinear forward model) and regularization. Here, we propose an adaptation of these techniques for the more challenging problem of intensity-only measurements. It involves a difficult nonconvex optimization problem where phase an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 80 1 شماره
صفحات -
تاریخ انتشار 2018