Evaluation of the TAS analyzer and the low-range heparin management test in patients undergoing extracorporeal membrane oxygenation.

نویسندگان

  • T M Ambrose
  • C A Parvin
  • E Mendeloff
  • L Luchtman-Jones
چکیده

BACKGROUND The new Low-Range Heparin Management Test (LHMT), a method for point-of-care testing (POCT) of heparinization, has been designed to function at the low to moderate heparin concentrations typically found in patients undergoing extracorporeal membrane oxygenation (ECMO). In this study, the new method is compared with two POCT methods and a laboratory-based anti-Xa assay. METHODS We obtained 760 whole blood samples from 13 patients undergoing ECMO. All samples were tested immediately by the LHMT, the Activated Clotting Time (ACT) test, and its low-range counterpart (ACT-LR). Aliquots from the same blood draw were frozen for later anti-Xa analysis using the Diagnostica Stago method on the Roche Cobas Fara-II. RESULTS The precision was best for duplicate citrated LHMT samples (CV = 3.1%). LHMT clotting times (overall median, 162 s) were typically shorter than ACT or ACT-LR times (247 and 235 s, respectively). The relationship between the LHMT and the other POCT methods differed significantly from patient to patient (P <0.0001), and a meaningful single relationship between the methods could not be obtained. The overall correlation coefficient between clotting time values and actual heparin concentrations was < or = 0.48 for each of the instruments tested, although time plots of each analyzer's data suggested that they detected heparin dosage changes within single patients. CONCLUSIONS The performance of the LHMT on the TAS Analyzer is equivalent to that of currently commercially available POCT methods. The lack of agreement between absolute clotting time values and heparin concentrations suggests the need for reexamination of current ECMO patient management strategy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term extracorporeal circulation management: the role of low- and high-range heparin ACT tests.

Modern management of extracorporeal circulation, especially during long-term support of post-cardiac surgical patients, remains challenging and requires optimal care of the patient's fluid balance and coagulation hemostasis for its successful outcome. The activated clotting time assay is one of the tests used to manage extracorporeal circulation and is available in a low- and high-range level. ...

متن کامل

[Evaluation of non-invasive hemoglobin measurements using the Masimo Rainbow Radical-7® device in a patient with extracorporeal membrane oxygenation].

Circulatory assist devices such as extracorporeal membrane oxygenation are indicated in cases of cardiogenic shock refractory to optimal conventional treatment. Bleeding is a serious complication of such systems, mainly due to coagulation disorders caused by continuous administration of heparin, as well as platelet dysfunction. Serial coagulation and hemoglobin (Hb) measurements are essential. ...

متن کامل

Suspected Heparin-Induced Thrombocytopenia in Patients Receiving Extracorporeal Membrane Oxygenation.

Heparin-induced thrombocytopenia (HIT) is an immune reaction usually secondary to unfractionated heparin. Anticoagulation management is critical in patients while on extracorporeal membrane oxygenation (ECMO) to prevent thromboembolism and for the optimal functioning of the circuit. We identified five patients with respiratory failure at our hospital managed with ECMO in the last 2 years that w...

متن کامل

First-year experience of a Brazilian tertiary medical center in supporting severely ill patients using extracorporeal membrane oxygenation

OBJECTIVES The aim of this manuscript is to describe the first year of our experience using extracorporeal membrane oxygenation support. METHODS Ten patients with severe refractory hypoxemia, two with associated severe cardiovascular failure, were supported using venous-venous extracorporeal membrane oxygenation (eight patients) or veno-arterial extracorporeal membrane oxygenation (two patien...

متن کامل

THE jOURNAL OF EXTRA-CORPOREAL TECHNOLOGY Technique Perfusion Strategies for Low-Dose and Heparin-Free Bypass

An increasing number of clinical reports are being published regarding various uses of heparin-bonded extracorporeal bypass circuits with altered coagulation regimens. Although the reasons for lowered heparinization levels have been discussed, there has been a lack of information detailing perfusion strategies necessary to manage this emerging technology. The decreased use or elimination of hep...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 47 5  شماره 

صفحات  -

تاریخ انتشار 2001